Sample type | Serum,plasma,milk,animal tissue,cells |
Sensitivity | 16.95 U/L |
Detection range | 16.95-3349 U/L |
Detection method | Colorimetric method |
Assay type | Enzyme Activity |
Assay time | 90 min |
Precision | Average inter-assay CV: 9.8%Average intra-assay CV: 4.5% |
Other instruments required | Vortex mixer, Micropipettor, Water bath, Incubator, Centrifuge |
Storage | 2-8℃ |
Valid period | 12 months |
It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (4.9-196.7 U/L).
The recommended dilution factor for different samples is as follows (for reference only):
Sample type |
Dilution factor |
Human serum |
1 |
Human plasma |
1 |
Rat serum |
1 |
5% Mouse brain tissue homogenization |
1 |
5% Mouse heart tissue homogenization |
1 |
Human milk |
1 |
Note: The diluent is reagent 2 application solution.
Sample: neutrophils |
DOI: 10.2147/JIR.S356960 |
|
Sample: Neutrophil |
Sample: serum |
PMID: 35031271 |
Sample: lung |
Sample: testicular tissue |
Sample: colon tissue |
Sample: colon |
PMID: 35322143 |
Sample: cortex |
PMID: 35105928 |
Sample: colon |
Sample: Cell culture supernatant,Tissue homogenate |
DOI: 10.1002/ptr.5965 |
|
Sample: Tissue homogenate |
DOI: 10.1155/2022/6205190 |
|
Sample: H9C2 cell |
PMID: 33310035 |
Sample: tissue |
Sample: Tissue homogenate |
DOI: 10.1002/iid3.466 |
|
PMID: 34102007 |
Sample: plasma |
Sample: neutrophils |
DOI: 10.1002/jez.2603 |
|
Sample: brain |
DOI: 10.1111/and.14455 |
|
PMID: 35560069 |
Sample: prostate tissue |
Sample: Tissue homogenate |
Sample: Tissue homogenate |
PMID: 34498709 |
Sample: serum,small intestinal |
Verified Customer
V****lSubmitted [ Feb 05 2020 ]
M*****aSubmitted [ Oct 20 2022 ]
Asked: Is there a way to prolong the shelf life to 12 months?
Reply
adminSubmitted [ Oct 20 2022 ]
Answered: Sorry, There is no way to extend the shelf life, which depends on the properties of the reagent.
M*****aSubmitted [ Sep 16 2022 ]
Asked: How many reactions can be done with this kit as you have mentioned 100 Assays (Can detect 50 samples without duplication) Can you please clarify.
Reply
adminSubmitted [ Sep 16 2022 ]
Answered: Because each sample is required for a control, it only detect 50 samples. 100Assays=50 sample tubes +50 control tubes (each sample need a control)