| Detection Principle | AchE catalyzes the hydrolysis of acetylcholine to form choline, and choline react with dithio p-nitrobenzoic acid (DTNB) to form 5-mercapto-nitrobenzoic acid (TNB). TNB has an absorption peak at 412nm. And the activity of AchE is calculated by measuring the increasing rate of absorbance at 412nm. | 
| Synonyms | AchE | 
| Sample Type | Serum,Plasma,Animal tissue,Cell | 
| Detection Method | Colorimetric method | 
| Detection Instrument | Microplate reader (optimum wavelength: 412 nm) | 
| Research Area | Amino Acids And Proteins | 
| Other Reagents Required | Normal saline (0.9% NaCl), PBS (0.01 mol/L, pH 7.4) | 
| Storage | This product can be stored at 2-8°C for 12 months with shading light. | 
| Valid Period | 12 months | 
| Sensitivity | 1.225 U/mL | 
| Detection Range | 1.225-490 U/mL | 
| Precision | inter-assay CV: 9.3% | intra-assay CV: 4.7% | 
| Sample Volume | 20 μL | 
| Assay Time | 20 min | 
The recommended dilution factor for different samples is as follows (for reference only):
| Sample Type | Dilution Factor | 
|---|---|
| Mouse serum | 8-20 | 
| Mouse plasma | 4-10 | 
| Human serum | 4-10 | 
| Human plasma | 4-10 | 
| Rat serum | 4-10 | 
| Dog serum | 4-10 | 
| Horse serum | 2-8 | 
| 10% Mouse liver tissue homogenate | 1 | 
| 10% Mouse kidney tissue homogenate | 1 | 
| 10% Mouse brain tissue homogenate | 2-8 | 
| 10% Crucian carp muscle tissue homogenate | 1 | 
The diluent is normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4). For the dilution of other sample types, please do pretest to confirm the dilution factor.
Other Clones
{{antibodyDetailsPage.numTotal}} Results
- 
                                    
                                    
                                    {{item.title}}
                                    
Citations ({{item.publications_count}}) Manual MSDS
Cat.No.:{{item.cat}}
{{index}} {{goods_show_value}}
 
Other Formats
{{formatDetailsPage.numTotal}} Results
- 
                                    
                                    
                                    {{item.title}}
                                    
Citations ({{item.publications_count}}) Manual MSDS
Cat.No.:{{item.cat}}
{{index}} {{goods_show_value}}
 
- 
                                    
                                    
IF:{{item.impact}}
Journal:{{item.journal}} ({{item.year}})
DOI:{{item.doi}}Reactivity:{{item.species}}
Sample Type:{{item.organization}}
 
- 
                                    
Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}
 
                            