Current Position:Home>>Kits>>Metabolism Assays>> Glutathione Reductase (GR) Activity Assay Kit
Cat.No.:E-BC-K099-S
Welcome to order from local distributors.
Protocols for metabolism assays
Add to cart Bulk requestFor research use only. Order now, ship in 3 days
Synonyms | GR |
Sample type | Serum,plasma,tissue,cells |
Sensitivity | 6.2 U/L |
Detection range | 6.2-320 U/L |
Detection method | Colorimetric method |
Assay type | Enzyme Activity |
Assay time | 90 min |
Precision | Average inter-assay CV: 2.500%Average intra-assay CV: 2.100% |
Other instruments required | Incubator, Vortex mixer, Micropipettor, Centrifuge |
Other reagents required | Normal saline (0.9% NaCl), PBS (0.01 M, pH 7.4) |
Storage | Reagent 1: 2-8℃, others: -20℃ |
Valid period | 12 months |
The activity of GR was significantly lower (*P<0.05) in arsenic treated group and increased in arsenic + melatonin group (#P<0.05) comparing to control.
N Abdollahzade et al found that melatonin attenuated oxidative DNA damage in rats and attenuate chronic arsenic neurotoxicity. Glutathione reductase (GR) activity of rat brain tissue was determined using GR activity assay kit (E-BC-K099-S).
It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (6.2-320 U/L).
The recommended dilution factor for different samples is as follows (for reference only):
Sample type |
Dilution factor |
Human serum |
1 |
Human plasma |
1 |
Mouse serum |
1 |
Mouse plasma |
1 |
Rat serum |
1 |
Rat plasma |
1 |
10% Mouse liver tissue homogenization |
1-3 |
10% Epipremnum aureum tissue homogenization |
1 |
Note: The diluent is double distilled water or MERGEFIELD 其他试剂 normal saline (0.9% NaCl).
PMID: 33548266 |
Sample: Cell sample |
PMID: 35633452 |
Sample: plasma |
PMID: 35443217 |
Sample: serum |
PMID: 31972360 |
Sample: Tissue homogenate |
Sample: liver |
PMID: 32220623 |
Sample: Tissue homogenate |
PMID: 33310035 |
Sample: cell |
Sample: SH-SY5Y cell |
DOI: 10.1002/jez.2603 |
|
Sample: brain |
p***tSubmitted [ Jan 13 2024 ]
Asked: Is this kit suitable for mouse sample, please let me know
Reply
adminSubmitted [ Jan 13 2024 ]
Answered: Our kit is non-species-specific and can detect mouse serum (plasma) samples.
O*************RSubmitted [ Jan 01 2024 ]
Asked: Is this kit suitable for plant sample, please let me know
Reply
adminSubmitted [ Jan 01 2024 ]
Answered: Our laboratory has verified that the green plant sample can be detected, and the measured value is 11.465U/gprot. There are differences between the samples. Theoretically, if the GR enzyme activity in the sample is higher than the sensitivity of the kit, it can be detected. It is recommended that you buy a small size kit to do a pre-test.
R**********nSubmitted [ Jul 13 2022 ]
Asked: Will the glutathione Reductase activity assay kit (E-BC-K099-S) work on an automated analyzer as an enzymatic reaction or other reaction type? Do you have a control for this test
Reply
adminSubmitted [ Jul 13 2022 ]
Answered: Sorry to inform you that our kits can not work on an automated analyzer and we don't have a control for this test.