Current Position:Home>>Kits>>Metabolism Assays>> H2S Colorimetric Assay Kit
Cat.No.:E-BC-K355-M
Welcome to order from local distributors.
Protocols for metabolism assays
Add to cart Bulk requestFor research use only. Order now, ship in 3 days
Synonyms | H2S |
Sample type | Serum,plasma,animal tissue |
Sensitivity | 2.75 μmol/L |
Detection range | 4.86-100 μmol/L |
Detection method | Colorimetric method |
Assay type | Quantitative |
Assay time | 80 min |
Precision | Average inter-assay CV: 9.900%Average intra-assay CV: 3.100% |
Other instruments required | Micropipettor, Centrifuge, Incubator, Vortex mixer |
Other reagents required | Normal saline (0.9% NaCl) |
Storage | 2-8℃ |
Valid period | 12 months |
H2S level in cell is significantly increased by dosage.
Y Q Zhang et al developed a hydrogen sulphide-responsive and depleting nanoplatform for cancer photodynamic therapy. H2S level in cell was determined using H2S colorimetric assay kit (E-BC-K355-M).
It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (6.82-100 μmol/L).
The recommended dilution factor for different samples is as follows (for reference only):
Sample type |
Dilution factor |
Human plasma |
1 |
Mouse plasma |
1 |
10% Rat spleen tissue homogenate |
1 |
10% Rat kidney tissue homogenate |
1 |
10% Rat brain tissue homogenate |
1 |
Note: The diluent is normal saline (0.9% NaCl).
PMID: 35354794 |
Sample: liver |
PMID: 34517587 |
Sample: H9C2 cells |
PMID: 35326383 |
Sample: plasma |
PMID: 34902580 |
Sample: gastric fundal tissue |
DOI: 10.1111/jcmm.15855 |
|
PMID: 32935914 |
Sample: Plasma,Tissue homogenate |
Sample: bladder tissue |
PMID: 30768962 |
Sample: Tissue homogenate |
DOI: 10.1002/nau.24333 |
|
Sample: Tissue homogenate |
DOI: 10.1111/and.13240 |
|
Sample: Tissue homogenate |
E***********mSubmitted [ Jun 08 2023 ]
Asked: Is there a difference in the product size 48T and 96T in the quantity of the reagents? because i want to get the kit for a single experiment and won\'t be needing it anymore
Reply
adminSubmitted [ Jun 08 2023 ]
Answered: Hello Esraa, Thanks for your valuable question, for the product #E-BC-K355-M, if perform the experiment according to its product manual, the product size 48T allows to detect 31 samples, and the product size 96T allows to detect 79 samples. The product lead time is 1-2 business days. Please let us know if we could be of any further assistance :)
M*****iSubmitted [ Oct 13 2022 ]
Asked: Can the sample be detected if it exceeds the detection range written on the instruction manual?
Reply
adminSubmitted [ Oct 13 2022 ]
Answered: Yes, but please dilute the sample for detection.
M*****iSubmitted [ Aug 17 2022 ]
Asked: Is the sample of plant tissue available?
Reply
adminSubmitted [ Aug 17 2022 ]
Answered: Unfortunately, this kit is not suitable for plant tissues.