Vitamin C (VC) Colorimetric Assay Kit (E-BC-K034-S)
                        For research use only.
| Detection Principle | The most obvious chemical activity of VC is that reduce Fe3+ to Fe2+, then promote iron absorption in the intestine, promote the storage and utilization of iron. Fe3+ react immediately with reducing ascorbic acid to form Fe2+. then Fe2+ react with phenanthroline and the color developing reaction occurs. The content of vitamin C in sample can be determined. Measure the OD value and calculate the VC content indirectly. | 
| Synonyms | Ascorbic acid;VC | 
| Sample Type | Serum,Plasma,Tissue | 
| Detection Method | Colorimetric method | 
| Detection Instrument | Spectrophotometer (536 nm) | 
| Research Area | Oxidative Stress , Plant Physiology Series | 
| Other Reagents Required | Normal saline (0.9% NaCl), PBS (0.01 mol/L, pH 7.4), Absolute ethanol | 
| Storage | This product can be stored at 2-8°C for 12 months with shading light. | 
| Valid Period | 12 months | 
| Sensitivity | 0.35 μg/mL | 
| Detection Range | 0.35-20 μg/mL | 
| Precision | inter-assay CV: 3.3% | intra-assay CV: 2.3% | 
| Sample Volume | 0.15 mL | 
| Assay Time | 1 h 20 min | 
The recommended dilution factor for different samples is as follows (for reference only):
| Sample Type | Dilution Factor | 
|---|---|
| Human serum | 1 | 
| Human plasma | 1 | 
| 10% Mouse kidney tissue homogenization | 1 | 
| Rat serum | 1 | 
| Mouse serum | 1 | 
| 10% Rat liver tissue homogenization | 1 | 
The diluent is normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4). For the dilution of other sample types, please do pretest to confirm the dilution factor.
Other Clones
{{antibodyDetailsPage.numTotal}} Results
- 
                                    
                                    
                                    {{item.title}}
                                    
Citations ({{item.publications_count}}) Manual MSDS
Cat.No.:{{item.cat}}
{{index}} {{goods_show_value}}
 
Other Formats
{{formatDetailsPage.numTotal}} Results
- 
                                    
                                    
                                    {{item.title}}
                                    
Citations ({{item.publications_count}}) Manual MSDS
Cat.No.:{{item.cat}}
{{index}} {{goods_show_value}}
 
- 
                                    
                                    
IF:{{item.impact}}
Journal:{{item.journal}} ({{item.year}})
DOI:{{item.doi}}Reactivity:{{item.species}}
Sample Type:{{item.organization}}
 
- 
                                    
Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}
 
                            
