Click here to view cell apoptosis assay products
×

Human Ang-Ⅱ(Angiotensin Ⅱ) ELISA Kit

  • Cat.No.:E-EL-H0326

  • Reactivity: Human

To Purchase E-EL-H0326

Size:
  • 96T
  • 48T
  • 24T
  • 96T*5
  • 96T*10
Price: $495
Qty:

Product Details

Properties

Assay type Competitive-ELISA
Format 96T/48T
Assay time 2.0h
Detection range 31.25-2000 pg/mL
Sensitivity 18.75 pg/mL
Sample type &Sample volume serum, plasma and other biological fluids; 50μL
Specificity This kit recognizes Ang-Ⅱ in samples. No significant cross-reactivity or interference between Ang-Ⅱ and analogues was observed.
Reproducibility Both intra-CV and inter-CV are < 10%.
Application This ELISA kit applies to the in vitro quantitative determination of Ang-Ⅱ concentrations in serum, plasma and other biological fluids.

Test Principle

This ELISA kit uses the Competitive-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with Ang-Ⅱ. During the reaction, Ang-Ⅱ in the sample or standard competes with a fixed amount of Ang-Ⅱ on the solid phase supporter for sites on the Biotinylated Detection Ab specific to Ang-Ⅱ. Excess conjugate and unbound sample or standard are washed away, and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns from blue to yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of Ang-Ⅱ in tested samples can be calculated by comparing the OD of the samples to the standard curve.

Kit components & Storage

An unopened kit can be stored at 2-8℃ for 1 month. If the kit is not supposed to be used within 1 month, store the components separately according to the following conditions once the kit is received.
ItemSpecificationsStorage
Micro ELISA Plate(Dismountable) 96T: 8 wells ×12 strips
48T: 8 wells ×6 strips
-20℃, 6 months
Reference Standard 96T: 2 vials
48T: 1 vial
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL
-20℃(Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL
HRP Conjugate Diluent 1 vial, 14 mL
Concentrated Wash Buffer (25×) 1 vial, 30 mL
Substrate Reagent 1 vial, 10 mL 2-8℃(Protect from light)
Stop Solution 1 vial, 10 mL 2-8℃
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Technical Data

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Ang-Ⅱ were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Ang-Ⅱ were tested on 3 different plates, 20 replicates in each plate.

  Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean (pg/mL) 101.10 272.50 948.90 108.40 291.70 898.00
Standard deviation 6.70 14.40 43.60 6.60 14.60 44.00
CV (%) 6.63 5.28 4.59 6.09 5.01 4.90

Recovery

The recovery of Ang-Ⅱ spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 88-103 95
EDTA plasma(n=8) 95-107 101
Cell culture media(n=8) 91-105 96

Linearity

Samples were spiked with high concentrations of Human Ang-Ⅱ and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.

Target Information

Database LinksSwissProt: P01019
SynonymsAngiotensin-2
Research AreaCancer, Cardiovascular, Metabolism, Signal transduction

Assay Procedures

elisa assay procedure 1

1. Add 50μL standard or sample to the wells, immediately add 50μL Biotinylated Detection Ab working solution to each well. Incubate for 45 min at 37°C

elisa assay procedure 2

2. Aspirate and wash the plate for 3 times

elisa assay procedure 3

3. Add 100μL HRP conjugate working solution. Incubate for 30 min at 37°C. Aspirate and wash the plate for 5 times

elisa assay procedure 4

4. Add 90μL Substrate Reagent. Incubate for 15 min at 37°C

elisa assay procedure 5

5. Add 50μL Stop Solution

elisa assay procedure 6

6. Read the plate at 450nm immediately. Calculation of the results

Citations

  1. JOURNAL OF HEADACHE AND PAIN (2021) IF: 7.277
    HMGB1, NLRP3, IL-6 and ACE2 levels are elevated in COVID-19 with headache: a window to the infection-related headache mechanism

    DOI: 10.1186/s10194-021-01306-7

    PMID: 34384355

    Sample: serum
  2. Frontiers in Endocrinology (2022) IF: 6.055
    Children With Short Stature Display Reduced ACE2 Expression in Peripheral Blood Mononuclear Cells

    DOI: 10.3389/fendo.2022.912064

    PMID: 35909539

    Sample: serum
  3. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES (2022) IF: 6.208
    Metformin Alleviates Epirubicin-Induced Endothelial Impairment by Restoring Mitochondrial Homeostasis

    DOI: 10.3390/ijms24010343

    Sample: Human Umbilical Vein Endothelial Cells (HUVECs)
  4. Journal of Translational Medicine (2021) IF: 5.531
    Pulmonary midkine inhibition ameliorates sepsis induced lung injury

    DOI: 10.1186/s12967-021-02755-z

    PMID: 33639987

    Sample: Plasma
  5. Frontiers in Pharmacology (2022) IF: 5.811
    Blocking VCAM-1 Prevents Angiotensin II-Induced Hypertension and Vascular Remodeling in Mice.

    DOI: 10.3389/fphar.2022.825459

    Sample: serum
  6. NUTRITION METABOLISM AND CARDIOVASCULAR DISEASES (2022) IF: 4.222
    Type 1 diabetes is associated with significant changes of ACE and ACE2 expression in peripheral blood mononuclear cells

    DOI: 10.1016/j.numecd.2022.01.029

    PMID: 35260304

    Sample: peripheral blood mononuclear cell
  7. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES (2020) IF: 4.556
    Sex Differences in Proatherogenic Cytokine Levels

    DOI: 10.3390/ijms21113861

    PMID: 32485823

    Sample: Serum
  8. Computational and Mathematical Methods in Medicine (2022) IF: 2.238
    Angiotensin II Mediates Cardiomyocyte Hypertrophy in Atrial Cardiomyopathy via Epigenetic Transcriptional Regulation

    DOI: 10.1155/2022/6312100

    PMID: 35756425

    Sample: heart tissue
Show AllShorten

Reviews/Q&A

  • Show all
  • Reviews
  • Q&A
... Show All Show Less

People Also Bought

Apply for Free Shipping 24T ELISA Kit
*Product Name:
*Catalog Number:
Size:
*Name:
*Email:
*Phone:
*Message:
*Country:
*When will you use it?

*Captcha: