Current Position:Home>>Kits>>Metabolism Assays>> Lactate Dehydrogenase (LDH) Activity Assay Kit
Cat.No.:E-BC-K046-M
Welcome to order from local distributors.
Protocols for metabolism assays
Add to cart Bulk requestFor research use only. Order now, ship in 3 days
Synonyms | LDH |
Sample type | Serum,plasma,hydrothorax,tissue,cells |
Sensitivity | 6 U/L |
Detection range | 6-1000 U/L |
Detection method | Colorimetric method |
Assay type | Enzyme Activity |
Assay time | 45 min |
Precision | Average inter-assay CV: 2.400%Average intra-assay CV: 1.800% |
Other instruments required | Micropipettor, Multichannel pipette, Incubator |
Other reagents required | Normal saline (0.9% NaCl), PBS (0.01 M, pH 7.4) |
Storage | 2-8℃ |
Valid period | 12 months |
The activity of LDH that shows the membrane leakage was significantly increased after treating with CuO. (**P<0.01 vs. Control, #P<0.05, ###P<0.001 vs. untreated group)
L A Jaragh-Alhadad et al investigates the neurotoxicity of copper oxide that may promote Alzheimer’s diseases. Lactate Dehydrogenase (LDH) activity of human cell was determined using LDH activity assay kit (E-BC-K046-M).
PMID: 34571217 |
Sample: liver organoids (LOs) |
PMID: 35489465 |
Sample: pig testicular cell (ST cell) |
PMID: 35259430 |
Sample: SH-SY5Y cell |
PMID: 33971320 |
Sample: Cell culture supernatant |
Sample: livers |
PMID: 36230124 |
Sample: serum |
PMID: 35616134 |
Sample: MLE-12 cell |
Sample: serum,HL-1 cell |
PMID: 34274339 |
Sample: serum |
DOI: 10.1002/cbin.11897 |
|
Sample: INS-1 cell |
PMID: 33827384 |
Sample: serum |
PMID: 36016223 |
Sample: PBMC |
Sample: Brain |
PMID: 34871743 |
Sample: serum |
Sample: rat thoracic aortic endothelial cells (RTAEC) |
DOI: 10.1530/REP-20-0381 |
|
PMID: 33112813 |
Sample: testis |
DOI: 10.1002/jgm.3200 |
|
Sample: H9c2 cell |
DOI: 10.1039/D0RA08538C |
|
Sample: Cell sample |
Sample: serum |
PMID: 35298730 |
Sample: serum |
Sample: serum |
Sample: Serum |
Sample: MC3T3-E1 cells |
DOI: 10.1155/2022/7832540 |
|
Sample: hepatic tissue,serum |
DOI: 10.1002/jez.2603 |
|
Sample: brain |
Sample: serum |
Sample: Serum |
DOI: 10.1002/jbt.22283 |
|
Sample: Serum |
PMID: 32978744 |
Sample: Serum |
Sample: serum |
Sample: Plasma |
Sample: Renal |
Sample: plasma |
Sample: serum |
Verified Customer
p****pSubmitted [ Jun 06 2019 ]
N************RSubmitted [ Aug 05 2023 ]
Asked: Is this kit appropriate for studying with plants (lichens)?
Reply
adminSubmitted [ Aug 05 2023 ]
Answered: We'll reply to you by email. Pls pay attention to the mailbox
M*****iSubmitted [ Oct 09 2022 ]
Asked: Why doesn\'t my standard curve go through the origin?
Reply
adminSubmitted [ Oct 09 2022 ]
Answered: Please use the absolute OD value for plotting.
M*****iSubmitted [ Aug 25 2022 ]
Asked: What is the minimum volume of sample? I\'m detecting mouse serum.
Reply
adminSubmitted [ Aug 25 2022 ]
Answered: A minimum volume of 40 uL is required.