Detection principle

Under the condition of weak acidity, non-esterified free fatty acids (NEFA) react with nantokite to form copper soap, which has a specific absorption peak at 715nm. The content of NEFA can be calculated by measuring the OD value at 715 nm.

Performance characteristics

Synonyms NEFA
Sample type Serum,animal tissue
Sensitivity 0.05 mmol/L
Detection range 0.05-2.0 mmol/L
Detection method Colorimetric method
Assay type Quantitative
Assay time 60 min
Precision Average inter-assay CV: 6.100%Average intra-assay CV: 2.200%
Other instruments required Vortex mixer, Micropipettor
Storage 2-8℃
Valid period 12 months

Dilution of sample

It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (0.05-2.0 mmol/L).

The recommended dilution factor for different samples is as follows (for reference only):

Sample type

Dilution factor

 Rat liver tissue homogenate

1-3

 Rat heart tissue homogenate

1

Rat kidney tissue homogenate

1

 Mouse liver tissue homogenate

1-3

Rat serum

1

Mouse serum

1

Human serum

1

Note: The diluent is Reagent 1.

Citations

  1. CELL (2023) IF: 66.849
    Light modulates glucose metabolism by a retina-hypothalamus-brown adipose tissue axis

    DOI: 10.1016/j.cell.2022.12.024

    PMID: 36669474

    Sample: Serum
  2. Engineering (2022) IF: 12.834
    Hydrogen Sulfide Promotes Adipocyte Differentiation, Hyperplasia, and Hypertrophy

    DOI: 10.1016/j.eng.2022.09.010

    Sample: adipose tissues,preadipocytes
  3. SCIENCE OF THE TOTAL ENVIRONMENT (2022) IF: 10.753
    Combined effect of polystyrene microplastics and bisphenol A on the human embryonic stem cells-derived liver organoids: The hepatotoxicity and lipid accumulation

    DOI: 10.1016/j.scitotenv.2022.158585

    PMID: 36089014

    Sample: liver organoids (LOs)
  4. DIABETES (2022) IF: 9.337
    PATAS, a First-in-Class Therapeutic Peptide Biologic, Improves Whole-Body Insulin Resistance and Associated Comorbidities In Vivo

    DOI: 10.2337/db22-0058

    PMID: 35822820

    Sample: blood
  5. iScience (2022) IF: 6.107
    MiR-203 is an anti-obese miRNA by targeting ASBT

    DOI: 10.1016/j.isci.2022.104708

    Sample: plasma
  6. Pharmaceutics (2022) IF: 6.525
    The Anti-Obesity Potential of Superparamagnetic Iron Oxide Nanoparticles against High-Fat Diet-Induced Obesity in Rats: Possible Involvement of Mitochondrial Biogenesis in the Adipose Tissues

    DOI: 10.3390/pharmaceutics14102134

    PMID: 36297569

    Sample: serum
  7. Frontiers in Pharmacology (2018) IF: 5.811
    Astragaloside IV Inhibits Triglyceride Accumulation in Insulin-Resistant HepG2 Cells via AMPK-Induced SREBP-1c Phosphorylation

    DOI: 10.3389/fphar.2018.00345

    Sample: HepG2 cells
  8. EUROPEAN JOURNAL OF PHARMACOLOGY (2021) IF: 4.432
    Fatty acid synthase inhibition ameliorates diabetes induced liver injury in rodent experimental model

    DOI: 10.1016/j.ejphar.2021.174078

    PMID: 33839087

    Sample: Serum
  9. Drug Design Development and Therapy (2020) IF: 3.216
    Radix Polygoni Multiflori and Its Main Component Emodin Attenuate Non-Alcoholic Fatty Liver Disease in Zebrafish by Regulation of AMPK Signaling Pathway

    DOI: 10.2147/DDDT.S243893

    Sample: Tissue homogenate
  10. ENVIRONMENTAL TOXICOLOGY AND PHARMACOLOGY (2020) IF: 3.292
    Chronic exposure of bisphenol A impairs carbohydrate and lipid metabolism by altering corresponding enzymatic and metabolic pathways

    DOI: 10.1016/j.etap.2020.103387

    PMID: 32339907

    Sample: Serum
  11. CLINICA CHIMICA ACTA (2019) IF: 2.735
    Serum albumin saturation test based on non-esterified fatty acids imbalance for clinical employment

    DOI: 10.1016/j.cca.2019.05.003

    Sample: serum
  12. SAUDI JOURNAL OF BIOLOGICAL SCIENCES (2020) IF: 2.802
    Anti-obesity potential of Moringa olifera seed extract and lycopene on high fat diet induced obesity in male Sprauge Dawely rats

    DOI: 10.1016/j.sjbs.2020.06.026

    PMID: 32994733

    Sample: Serum
  13. MOLECULAR GENETICS AND GENOMICS (2023) IF: 2.98
    Regulation of PPARγ/CPT-1 expression ameliorates cochlear hair cell injury by regulating cellular lipid metabolism and oxidative stress

    DOI: 10.1007/s00438-023-01993-8

    Sample: House Ear Institute-Organ of Corti 1 cells (HEI-OC
  14. TOXICOLOGY AND INDUSTRIAL HEALTH (2020) IF: 1.708
    Elevated, sustained, and yet reversible biotoxicity effects of lead on cessation of exposure: Melatonin is a potent therapeutic option:

    DOI: 10.1177/0748233720937199

    Sample: Plasma
Show AllShorten

Reviews/Q&A

  • Show all
  • Reviews
  • Q&A

Verified Customer

l***sSubmitted [ May 29 2019 ]

  • Application:Biochemical
  • Description:I used this biochemical kit to detect the content of free fatty acids in the liver of rats, and the experimental results could be obtained quickly according to the operation steps in the kit instructions.The formula notes in the specification are detailed, and the calculated results are clear and accurate.The sample took a little longer to process, and overall, the kit was excellent.
Read More
Read Less

Verified Customer

M*ySubmitted [ May 29 2019 ]

  • Application:Biochemical
  • Description: kit is accuracy and good reliability ,but the operation is a bit complicated and take a long time to extract samples
Read More
Read Less
Q

M**********dSubmitted [ Aug 12 2022 ]

Asked: How many cells do I need for an assay?

Reply

A

adminSubmitted [ Aug 12 2022 ]

Answered: At least 10^7 cells is required based on the cell types.

Q

D********dSubmitted [ Aug 01 2022 ]

Asked: Can I use microplate reader for the detection?

Reply

A

adminSubmitted [ Aug 01 2022 ]

Answered: If you'd like to measure by microplate reader, I highly recommend E-BC-K013-M which is designed for microplate reader measurement.

A

adminSubmitted [ Aug 01 2022 ]

Answered: If you'd like to measure by microplate reader, I highly recommend E-BC-K013-M which is designed for microplate reader measurement.

... Show All Show Less

People Also Bought

Apply for FREE TRIAL Fluorometric Assay kit
*Product Name:
*Catalog Number:
*Name:
*Email:
*Message:
*Country:
*When will you use it?

*Captcha: