Current Position:Home>>Kits>>ELISA Kits>> Rat GC(Glucagon) ELISA Kit
Cat.No.:E-EL-R0425
Welcome to order from local distributors.
Add to cart Bulk requestFor research use only. Order now, ship in 3 days
Assay type | Competitive-ELISA |
Format | 96T/48T |
Assay time | 2.0h |
Detection range | 62.50-4000 pg/mL |
Sensitivity | 37.50 pg/mL |
Sample type &Sample volume | serum, plasma and other biological fluids; 50μL |
Specificity | This kit recognizes GC in samples. No significant cross-reactivity or interference between GC and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are < 10%. |
Application | This ELISA kit applies to the in vitro quantitative determination of GC concentrations in serum, plasma and other biological fluids. |
Item | Specifications | Storage |
---|---|---|
Micro ELISA Plate(Dismountable) | 96T: 8 wells ×12 strips
48T: 8 wells ×6 strips |
-20℃, 6 months |
Reference Standard | 96T: 2 vials
48T: 1 vial |
|
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL |
|
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL |
-20℃(Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | |
Substrate Reagent | 1 vial, 10 mL | 2-8℃(Protect from light) |
Stop Solution | 1 vial, 10 mL | 2-8℃ |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy |
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level GC were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level GC were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (pg/mL) | 205.30 | 401.50 | 1351.70 | 185.10 | 391.80 | 1483.10 |
Standard deviation | 11.70 | 17.30 | 58.10 | 9.80 | 18.00 | 60.80 |
CV (%) | 5.70 | 4.31 | 4.30 | 5.29 | 4.59 | 4.10 |
The recovery of GC spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
---|---|---|
Serum(n=8) | 92-107 | 98 |
EDTA plasma(n=8) | 92-104 | 98 |
Cell culture media(n=8) | 95-106 | 101 |
Samples were spiked with high concentrations of Rat GC and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Synonyms | GCG, GRPP |
Research Area | Cancer, Metabolism, Developmental biology, Signal transduction, Stem cells |
![]() |
1. Add 50μL standard or sample to the wells, immediately add 50μL Biotinylated Detection Ab working solution to each well. Incubate for 45 min at 37°C |
![]() |
2. Aspirate and wash the plate for 3 times |
![]() |
3. Add 100μL HRP conjugate working solution. Incubate for 30 min at 37°C. Aspirate and wash the plate for 5 times |
![]() |
4. Add 90μL Substrate Reagent. Incubate for 15 min at 37°C |
![]() |
5. Add 50μL Stop Solution |
![]() |
6. Read the plate at 450nm immediately. Calculation of the results |
From now on, if you have published a paper by using any of our products since 1/1/2019, fill out the “Elabscience Publication Reward Application Form”carefully and send it to orders@elabscience.com, we will get back to you with the reward after we confirm it ASAP!
PMID: 33304464 |
Sample: plasma |
DOI: 10.3390/ijms24032169 |
|
Sample: plasma |
Sample: plasma |
PMID: 35914653 |
Sample: islet |
Sample: plasma |
DOI: 10.3390/ijms22105400 |
|
PMID: 34065591 |
Sample: Plasma |
PMID: 33776655 |
Sample: Serum |
DOI: 10.4314/ajtcam.v13i5 |
|
Sample: plasma |
Sample: blood |