Current Position:Home>>Kits>>ELISA Kits>> T(Testosterone) ELISA Kit
Cat.No.:E-EL-0155
Welcome to order from local distributors.
Add to cart Bulk requestFor research use only. Order now, ship in 3 days
Assay type | Competitive-ELISA |
Format | 96T/48T |
Assay time | 2.0h |
Detection range | 0.31-20 ng/mL |
Sensitivity | 0.17 ng/mL |
Sample type &Sample volume | serum, plasma, urine, saliva; 50μL |
Specificity | This kit recognizes T in samples. No significant cross-reactivity or interference between T and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are < 10%. |
Application | This ELISA kit applies to the in vitro quantitative determination of T concentrations in serum, plasma, urine, saliva. |
Item | Specifications | Storage |
---|---|---|
Micro ELISA Plate(Dismountable) | 96T: 8 wells ×12 strips
48T: 8 wells ×6 strips |
-20℃, 6 months |
Reference Standard | 96T: 2 vials
48T: 1 vial |
|
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL |
|
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL |
-20℃(Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | |
Substrate Reagent | 1 vial, 10 mL | 2-8℃(Protect from light) |
Stop Solution | 1 vial, 10 mL | 2-8℃ |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy |
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level T were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level T were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (ng/mL) | 1.33 | 5.22 | 10.88 | 1.54 | 5.73 | 10.02 |
Standard deviation | 0.11 | 0.35 | 0.46 | 0.14 | 0.35 | 0.68 |
CV (%) | 8.13 | 6.72 | 4.27 | 9.23 | 6.18 | 6.75 |
The recovery of T spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
---|---|---|
Serum(n=8) | 80-90 | 84 |
EDTA plasma(n=8) | 82-94 | 87 |
Urine(n=8) | 85-102 | 95 |
Samples were spiked with high concentrations of T and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
![]() |
1. Add 50μL standard or sample to the wells, immediately add 50μL Biotinylated Detection Ab working solution to each well. Incubate for 45 min at 37°C |
![]() |
2. Aspirate and wash the plate for 3 times |
![]() |
3. Add 100μL HRP conjugate working solution. Incubate for 30 min at 37°C. Aspirate and wash the plate for 5 times |
![]() |
4. Add 90μL Substrate Reagent. Incubate for 15 min at 37°C |
![]() |
5. Add 50μL Stop Solution |
![]() |
6. Read the plate at 450nm immediately. Calculation of the results |
From now on, if you have published a paper by using any of our products since 1/1/2019, fill out the “Elabscience Publication Reward Application Form”carefully and send it to orders@elabscience.com, we will get back to you with the reward after we confirm it ASAP!
PMID: 33162236 |
Sample: Serum |
PMID: 35177090 |
Sample: Serum,Cell culture supernatant |
Sample: Plasma |
PMID: 30411254 |
Sample: Cell culture supernatant |
DOI: 10.1039/d1fo01744f |
|
PMID: 35044398 |
Sample: Serum |
PMID: 29072679 |
Sample: Serum |
DOI: 10.1159/000457881 |
|
PMID: 28214901 |
Sample: Serum |
PMID: 34280466 |
Sample: Serum |
DOI: 10.1039/c9fo02554e |
|
PMID: 32441726 |
Sample: Serum |
DOI: 10.3390/ijms20030630 |
|
PMID: 30717178 |
Sample: Tissue homogenate |
PMID: 30833257 |
Sample: Plasma |
DOI: 10.1042/CS20180179 |
|
PMID: 29572383 |
DOI: 10.1038/srep43475 |
|
PMID: 28276438 |
Sample: Serum |
PMID: 27746685 |
Sample: Serum |
PMID: 28039834 |
Sample: Plasma |
PMID: 32544536 |
Sample: Plasma |
PMID: 31899225 |
Sample: Serum |
PMID: 30195209 |
Sample: Serum |
PMID: 30641075 |
Sample: Serum,Cell culture medium |
PMID: 30658301 |
Sample: Serum |
PMID: 30384460 |
Sample: Serum |
PMID: 32488017 |
Sample: Plasma,Tissue homogenate |
PMID: 32659591 |
Sample: Serum |
PMID: 29197623 |
Sample: Serum |
PMID: 24440814 |
Sample: Serum |
PMID: 32725591 |
Sample: Serum |
Sample: Serum |
PMID: 30431108 |
Sample: Serum |
DOI: 10.1002/jat.3764 |
|
PMID: 30565266 |
Sample: Serum |
PMID: 30648235 |
Sample: Serum |
PMID: 30483787 |
Sample: Serum |
DOI: 10.1002/tox.22559 |
|
PMID: 29663635 |
Sample: Tissue homogenate |
PMID: 25784152 |
Sample: Plasma |
PMID: 29125859 |
Sample: Cell culture supernatant |
PMID: 26081124 |
Sample: Serum |
DOI: 10.1111/jfbc.13385 |
|
Sample: Tissue homogenate |
Sample: Plasma |
PMID: 30214533 |
Sample: Serum |
PMID: 27600729 |
Sample: Serum |
PMID: 27600729 |
Sample: Serum |
PMID: 32659591 |
Sample: Serum |
Sample: Serum |
Sample: Serum |
Sample: Serum |
G*****dSubmitted [ May 03 2022 ]
Asked: Hello, In the ELISA kit E-EL-0155, did we measure free or total testosterone ? Best regards, Geraldine
Reply
adminSubmitted [ May 03 2022 ]
Answered: Hi Geraldine, this kit measures Total Testosterone. Feel free to contact us if you have any other questions.