Toll-free:1-888-852-8623

All categories

  • All categories
  • Flow Cytometry Antibodies
  • ELISA Kits
  • MACS Cell Isolation
  • Antibodies and Reagents
  • Apoptosis and Cell Health Detection
  • Metabolism Assays
  • Immunoassays
  • Cell Identification Kits
  • Proteins and Peptides
  • Cell Culture
Please enter the item number/product keyword!
Keyword cannot be empty !
INSERT SYMBOLS:
  • α
  • β
  • γ
  • δ
  • ε
  • ζ
  • η
  • θ
  • κ
  • μ
  • ω
  • σ
  • τ
  • λ
  • ⅩⅢ
  • ⅩⅢ
  • ⅩⅣ
  • ⅩⅤ
  • ⅩⅦ
  • ⅩⅧ
  • UP ↑

Hdroxyproline (HYP) Colorimetric Assay Kit (Alkali Hydrolysis Method) (E-BC-K061-M)

All Size Price Qty
96T $ 360.00
48T $ 240.00
Add to cart

For research use only.

Detection Principle Hydroxyproline (HYP) is a derivative of proline, mainly found in collagen. Collagen is the most abundant protein in animals and makes up connective tissues such as skin, bone, cartilage, tendons and ligaments. HYP enhances the crosslinking of collagen fibers through the hydroxyl group in its structure, thus improving the stability and tensile strength of collagen. Since HYP almost only exists in collagen, its content can reflect the synthesis and catabolism of collagen. Therefore, the detection of HYP level can be used as an indicator to monitor collagen metabolism.
The detection principle of this kit: the sample is hydrolyzed by the alkali reagent to generate free HYP, and the oxidation product produced under the action of the oxidant reacts with the color agent to be purple red. The substance has an absorption peak at 565 nm, and within a certain range, its absorbance is linear with the concentration. By measuring the absorbance at 565 nm, the HYP content in the sample can be calculated.
Sample Type Serum,Plasma,Animal tissue
Detection Method Colorimetric method
Detection Instrument Microplate reader (555-565 nm, optimum wavelength: 565 nm)
Research Area Amino Acids And Proteins
Storage This product can be stored at 2-8°C for 12 months with shading light.
Valid Period 12 months
Sensitivity 0.036 μg/mL
Detection Range 0.036-5 μg/mL
Precision inter-assay CV: 2.4-3.4% | intra-assay CV: 1.4-2.1%
Sample Volume 1 mL
Assay Time 2 h
Cat.No. Product Name Sizes
E-BC-K062-M Hydroxyproline (HYP) Colorimetric Assay Kit (Acid Hydrolysis Method) 96T , 48T

The recommended dilution factor for different samples is as follows (for reference only):

Sample Type Dilution Factor
Human serum 1
Rat serum 1
Rat plasma 1
Fish scale 4-10
Fin tissue 4-10
Fishtail tissue 4-10
Mouse lung tissue 1
Mouse muscle tissue 2-5
Mouse leg bone tissue 4-10

The diluent is normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4). For the dilution of other sample types, please do pretest to confirm the dilution factor.

Other Clones

{{antibodyDetailsPage.numTotal}} Results

Other Formats

{{formatDetailsPage.numTotal}} Results

  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.organization}}

detection instrument

{{assayDetailsPage.numTotal}} Results

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}