Human AGGF1 (Angiogenic Factor with G Patch and FHA Domains 1) CLIA Kit (E-CL-H0172)

Human AGGF1 (Angiogenic Factor with G Patch and FHA Domains 1) CLIA Kit - 1
  • Human AGGF1 (Angiogenic Factor with G Patch and FHA Domains 1) CLIA Kit - 1
  • Human AGGF1 (Angiogenic Factor with G Patch and FHA Domains 1) CLIA Kit - 2
  • Human AGGF1 (Angiogenic Factor with G Patch and FHA Domains 1) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 18.75 pg/mL
Detection Range 31.25-2000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human AGGF1 in samples.No significant cross-reactivity or interference between Human AGGF1 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
2000 56011.000 60877.000 58444.000 58425
1000 23807.000 25055.000 24431.000 24412
500 12199.000 10353.000 11276.000 11257
250 5327.000 6263.000 5795.000 5776
125 2986.000 2626.000 2806.000 2787
62.5 1485.000 1337.000 1411.000 1392
31.25 699.000 757.000 728.000 709
0 18.000 20.000 19.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 107.420 208.770 827.420 113.140 209.480 818.850
Standard deviation 12.570 16.970 75.960 13.360 14.790 73.700
CV(%) 11.700 8.130 9.180 11.810 7.060 9.000
Recovery
The recovery of Human AGGF1 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 88-103 95
EDTA plasma (n=8) 95-107 102
Cell culture media (n=8) 97-113 103
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human AGGF1 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 96-112 87-101 97-112
Average 102 94 103
1:4 Range 89-103 100-112 84-95
Average 95 105 90
1:8 Range 98-110 89-104 93-108
Average 104 95 101
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human AGGF1. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human AGGF1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human AGGF1, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human AGGF1. You can calculate the concentration of Human AGGF1 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 55109
Uniport ID Q8N302
Research Area Cardiovascular
Human AGGF1 (Angiogenic Factor with G Patch and FHA Domains 1) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定