Human Ang-Ⅱ(Angiotensin Ⅱ) ELISA Kit - 1
  • Human Ang-Ⅱ(Angiotensin Ⅱ) ELISA Kit - 1
  • Human Ang-Ⅱ(Angiotensin Ⅱ) ELISA Kit - 2
  • Human Ang-Ⅱ(Angiotensin Ⅱ) ELISA Kit - 3
All Size Price Qty
96T $ 495.00
- +
48T $ 396.00
- +
24T $ 150.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 18.75 pg/mL
Detection Range 31.25-2000 pg/mL
Sample Volume 50 μL
Total Assay Time 2 h 30 min
Reactivity Human
Specificity This kit recognizes Human Ang-Ⅱ in samples.No significant cross-reactivity or interference between Human Ang-Ⅱ and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Colorimetric method, ELISA, Competitive
Assay Type Competitive-ELISA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃
Expiration Date 12 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
2000 0.269 0.283 0.276 -
1000 0.424 0.406 0.415 -
500 0.646 0.636 0.641 -
250 0.929 0.943 0.936 -
125 1.283 1.255 1.269 -
62.5 1.565 1.619 1.592 -
31.25 1.877 1.835 1.856 -
0 2.198 2.230 2.214 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 107.940 280.870 824.900 112.220 265.990 845.010
Standard deviation 5.960 16.820 35.640 7.920 21.010 65.570
CV(%) 5.520 5.990 4.320 7.060 7.900 7.760
Recovery
The recovery of Human Ang-Ⅱ was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 88-103 95
EDTA plasma (n=8) 95-107 101
Cell culture media (n=8) 91-105 96
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human Ang-Ⅱ and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 92-105 87-102 97-113
Average 97 93 105
1:4 Range 99-117 87-100 82-97
Average 107 94 89
1:8 Range 92-110 86-98 89-103
Average 100 92 95
Stability
Each kit batch is subjected to accelerated stability testing and real-time stability monitoring. Sample performance is evaluated after storage at 37 °C for 10 days to assess the impact of elevated temperature on assay reliability and reagent integrity.
/ Variation range of 37°C mean
concentration / 2-8°C mean
Sample 1(n=16) 91.29-100.21
Sample 2(n=16) 98.05-98.79
This ELISA kit uses the Competitive-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with Human Ang-Ⅱ. During the reaction, Human Ang-Ⅱ in the sample or standard competes with a fixed amount of Human Ang-Ⅱ on the solid phase supporter for sites on the Biotinylated Detection Ab specific to Human Ang-Ⅱ. Excess conjugate and unbound sample or standard are washed away, and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns from blue to yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of Human Ang-Ⅱ in tested samples can be calculated by comparing the OD of the samples to the standard curve.
Gene ID 183
Uniport ID P01019
Research Area Cancer , Cardiovascular , Metabolism , Signal Transduction
Human Ang-Ⅱ(Angiotensin Ⅱ) ELISA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

Species

{{relatedElisaPage.numTotal}} Results

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定