Facebook

All categories

  • All categories
  • Flow Cytometry Antibodies
  • Immunoassays
  • Antibodies and Reagents
  • Cell Identification Kits
  • Cell Isolation Products
  • Cell Health and Metabolism Assay Kits
  • Proteins and Peptides
  • Cell Culture
Please enter the item number/product keyword!
Keyword cannot be empty !
INSERT SYMBOLS:
  • α
  • β
  • γ
  • δ
  • ε
  • ζ
  • η
  • θ
  • κ
  • μ
  • ω
  • σ
  • τ
  • λ
  • ⅩⅢ
  • ⅩⅢ
  • ⅩⅣ
  • ⅩⅤ
  • ⅩⅦ
  • ⅩⅧ
  • UP ↑

Rat AGER (Total Advanced Glycosylation End Product Specific Receptor) CLIA Kit (E-CL-R0466)

Rat AGER (Total Advanced Glycosylation End Product Specific Receptor) CLIA Kit - 1
  • Rat AGER (Total Advanced Glycosylation End Product Specific Receptor) CLIA Kit - 1
  • Rat AGER (Total Advanced Glycosylation End Product Specific Receptor) CLIA Kit - 2
  • Rat AGER (Total Advanced Glycosylation End Product Specific Receptor) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 7.5 pg/mL
Detection Range 12.5-800 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Rat
Specificity This kit recognizes Rat AGER in samples.No significant cross-reactivity or interference between Rat AGER and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
800 51887.000 61823.000 56855.000 56823
400 20314.000 24696.000 22505.000 22473
200 10904.000 9402.000 10153.000 10121
100 4750.000 4794.000 4772.000 4740
50 2421.000 2391.000 2406.000 2374
25 1147.000 1003.000 1075.000 1043
12.5 505.000 541.000 523.000 491
0 30.000 34.000 32.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 41.300 122.880 267.750 39.890 130.590 287.000
Standard deviation 4.830 13.820 19.490 4.230 10.770 23.820
CV(%) 11.690 11.250 7.280 10.600 8.250 8.300
Recovery
The recovery of Rat AGER was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 98-116 106
EDTA plasma (n=8) 86-100 94
Cell culture media (n=8) 94-109 101
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Rat AGER and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 101-118 97-113 100-113
Average 109 103 107
1:4 Range 91-105 95-107 95-112
Average 96 101 102
1:8 Range 84-99 101-115 85-97
Average 90 108 92
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Rat AGER. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat AGER and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat AGER, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Rat AGER. You can calculate the concentration of Rat AGER in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 81722
Uniport ID Q63495
Research Area Cancer , Cardiovascular , Neuroscience
Rat AGER (Total Advanced Glycosylation End Product Specific Receptor) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定