For research use only.

Detection Principle Under acid conditions, the oxidizing material in the sample can oxidize Fe2+ to Fe3+, which binds highly with xylenol orange to produce a blue-purple complex. When the pH of solution is in the range of 2-3, its maximum absorption wavelength is around 590 nm, and the color depth is proportional to the content of oxidation substances in a certain concentration and a certain time, so as to indirectly calculate the total oxidation state of the sample.
Synonyms TOS
Sample Type Cell,Tissue,Serum,Other liquid sample
Detection Method Colorimetric method
Detection Instrument Microplate reader (580-590 nm, optimum wavelength: 590 nm)
Research Area Oxidative Stress
Other Reagents Required Normal saline (0.9% NaCl), PBS (0.01 mol/L, pH 7.4)
Storage This product can be stored at 2-8°C for 12 months with shading light.
Valid Period 12 months
Sensitivity 2.5 μmol H<sub>2</sub>O<sub>2</sub> Equiv./L
Detection Range 2.5-100 μmol H<sub>2</sub>O<sub>2</sub> Equiv./L
Precision inter-assay CV: 3.5% | intra-assay CV: 2.3%
Sample Volume 20 μL
Assay Time 30 min

The recommended dilution factor for different samples is as follows (for reference only):

Sample Type Dilution Factor
Human serum 1
Porcine serum 1
Horse serum 1
Cynomolgus macaques serum 1
10% Rat liver tissue homogenate 1
10% Rat kidney tissue homogenate 1
10% Rat lung tissue homogenate 1
10% Rat spleen tissue homogenate 1
0.612 × 10^6 Molt-4 cells 1

The diluent is normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4). For the dilution of other sample types, please do pretest to confirm the dilution factor.

Other Clones

{{antibodyDetailsPage.numTotal}} Results

Other Formats

{{formatDetailsPage.numTotal}} Results

  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.organization}}

detection instrument

{{assayDetailsPage.numTotal}} Results

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}