Click here to view cell apoptosis assay products
×

Bradford Protein Colorimetric Assay Kit

  • Cat.No.:E-BC-K168-M

  • Detection instrument: Microplate reader(550 nm-630 nm, optimum wavelength: 595 nm)

To Purchase E-BC-K168-M

Size:
  • 96T
  • 500Assays
Price: $100
Qty:

Welcome to order from local distributors.

Protocols for metabolism assays

FAQ for metabolism assays

Have Questions?

 Add to cart Bulk request

For research use only. Order now, ship in 3 days

Detection principle

Coomassie brilliant blue G-250 is red under the free state, and it has the maximum absorbance at 465 nm. When the Coomassie brilliant blue G-250 combined to protein, the compound will have the maximum at 595 nm. The absorbance value is directly proportional to the protein content, so the concentration of total protein can be calculated directly by measuring the OD value at 595 nm.

Performance characteristics

Synonyms TP
Sample type Serum,plasma,animal tissue and cell
Sensitivity 0.046 mg/mL
Detection range 0.046-0.6 mg/mL
Detection method Colorimetric method
Assay type Quantitative
Assay time 20 min
Precision Average inter-assay CV: 8.200%Average intra-assay CV: 3.200%
Other instruments required Micropipettor, Incubator, Vortex mixer, Centrifuge
Other reagents required Normal saline (0.9% NaCl), PBS (0.01 M, pH 7.4)
Storage Reagent 2: RT, Reagent 1: 2-8℃
Valid period 12 months

Dilution of sample

It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range ( MERGEFIELD Detection_range 0.046-0.6 mg/mL).

The recommended dilution factor for different samples is as follows (for reference only):

Sample type

Dilution factor

Human serum

90-110

Human plasma

90-110

Rabbit serum

90-110

Rat plasma

90-110

Chicken serum

90-110

10% Mouse kidney tissue homogenate

15-20

10% Mouse lung tissue homogenate

15-20

10% Rat spleen tissue homogenate

15-20

10% Rat heart tissue homogenate

15-20

10% Rat liver tissue homogenate

20-25

293T

1

HL-60

1

Note: The diluent is normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4).


Citations

  1. Journal of Oleo Science (2022) IF: 1.628
    Chemoprotective Effect of Decalactone on Hepatic Cancer via Diminishing the Inflammatory Response and Oxidative Stress

    DOI: 10.5650/jos.ess22033

    PMID: 35965085

    Sample: serum

Reviews/Q&A

  • Show all
  • Reviews
  • Q&A
Q

M*****aSubmitted [ Aug 31 2022 ]

Asked: Can the plate in this kit be replaced with our own 96-well plate?

Reply

A

adminSubmitted [ Aug 31 2022 ]

Answered: Yes, it can be replaced with the same type of microplate.

Q

M*****aSubmitted [ Aug 17 2022 ]

Asked: Can the kit work on plant sample?

Reply

A

adminSubmitted [ Aug 17 2022 ]

Answered: No, it can not detect the plant sample, But there is E-BC-K318-M which is suitable for plant tissue.