Human 5-LO (Arachidonate 5-Lipoxygenase) CLIA Kit (E-CL-H0197)

Human 5-LO (Arachidonate 5-Lipoxygenase) CLIA Kit - 1
  • Human 5-LO (Arachidonate 5-Lipoxygenase) CLIA Kit - 1
  • Human 5-LO (Arachidonate 5-Lipoxygenase) CLIA Kit - 2
  • Human 5-LO (Arachidonate 5-Lipoxygenase) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 37.5 pg/mL
Detection Range 62.5-4000 pg/mL
Sample Volume 100 μL
Total Assay Time 4 h 30 min
Reactivity Human
Specificity This kit recognizes Human 5-LO in samples.No significant cross-reactivity or interference between Human 5-LO and analogues was observed
Recovery 80%-120%
Sample Type Tissue homogenates, cell lysates and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
4000 56540.000 68590.000 62565.000 62533
2000 28206.000 28238.000 28222.000 28190
1000 15493.000 13463.000 14478.000 14446
500 7149.000 7327.000 7238.000 7206
250 3659.000 3157.000 3408.000 3376
125 1852.000 1624.000 1738.000 1706
62.5 807.000 853.000 830.000 798
0 32.000 32.000 32.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 211.920 560.500 1338.770 205.800 603.970 1412.790
Standard deviation 24.220 60.370 82.600 18.520 50.910 127.570
CV(%) 11.430 10.770 6.170 9.000 8.430 9.030
Recovery
The recovery of Human 5-LO was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 84-98 91
EDTA plasma (n=8) 94-108 99
Cell culture media (n=8) 88-100 95
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human 5-LO and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 97-113 95-111 95-110
Average 104 102 102
1:4 Range 99-117 93-108 100-120
Average 107 100 109
1:8 Range 98-111 91-102 101-115
Average 105 97 107
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human 5-LO. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human 5-LO and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human 5-LO, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human 5-LO. You can calculate the concentration of Human 5-LO in the samples by comparing the RLU value of the samples to the standard curve.
Human 5-LO (Arachidonate 5-Lipoxygenase) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定