Human ACE2 (Angiotensin I Converting Enzyme 2) CLIA Kit (E-CL-H0233)

Human ACE2 (Angiotensin I Converting Enzyme 2) CLIA Kit - 1
  • Human ACE2 (Angiotensin I Converting Enzyme 2) CLIA Kit - 1
  • Human ACE2 (Angiotensin I Converting Enzyme 2) CLIA Kit - 2
  • Human ACE2 (Angiotensin I Converting Enzyme 2) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 46.88 pg/mL
Detection Range 78.13-5000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human ACE2 in samples.No significant cross-reactivity or interference between Human ACE2 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
5000 60677.000 71849.000 66263.000 66229
2500 33721.000 35865.000 34793.000 34759
1250 20670.000 19202.000 19936.000 19902
625 10025.000 10343.000 10184.000 10150
312.5 5244.000 4506.000 4875.000 4841
156.25 2722.000 2690.000 2706.000 2672
78.13 1394.000 1444.000 1419.000 1385
0 33.000 35.000 34.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 264.480 543.750 1692.470 286.760 519.370 1672.550
Standard deviation 23.700 59.210 149.950 31.080 37.130 192.180
CV(%) 8.960 10.890 8.860 10.840 7.150 11.490
Recovery
The recovery of Human ACE2 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 101-114 108
EDTA plasma (n=8) 86-100 92
Cell culture media (n=8) 89-101 94
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human ACE2 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 90-105 87-101 92-103
Average 97 93 98
1:4 Range 101-116 85-99 100-114
Average 108 92 106
1:8 Range 98-116 92-104 96-108
Average 106 98 102
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human ACE2. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ACE2 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ACE2, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human ACE2. You can calculate the concentration of Human ACE2 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 59272
Uniport ID Q9BYF1
Research Area Cancer , Cell Biology , Cardiovascular
Human ACE2 (Angiotensin I Converting Enzyme 2) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定