Human ADAM10 (A Disintegrin And Metalloprotease 10) CLIA Kit (E-CL-H0219)

Human ADAM10 (A Disintegrin And Metalloprotease 10) CLIA Kit - 1
  • Human ADAM10 (A Disintegrin And Metalloprotease 10) CLIA Kit - 1
  • Human ADAM10 (A Disintegrin And Metalloprotease 10) CLIA Kit - 2
  • Human ADAM10 (A Disintegrin And Metalloprotease 10) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 9.38 pg/mL
Detection Range 15.63-1000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human ADAM10 in samples.No significant cross-reactivity or interference between Human ADAM10 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
1000 52548.000 57612.000 55080.000 55058
500 21327.000 25569.000 23448.000 23426
250 11345.000 9813.000 10579.000 10557
125 4882.000 5024.000 4953.000 4931
62.5 2584.000 2442.000 2513.000 2491
31.25 1359.000 1235.000 1297.000 1275
15.63 728.000 744.000 736.000 714
0 21.000 23.000 22.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 52.750 132.960 367.030 57.500 136.900 386.750
Standard deviation 6.470 13.240 33.180 6.660 15.940 23.590
CV(%) 12.270 9.960 9.040 11.580 11.640 6.100
Recovery
The recovery of Human ADAM10 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 95-106 101
EDTA plasma (n=8) 91-107 97
Cell culture media (n=8) 92-106 97
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human ADAM10 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 99-111 84-98 102-119
Average 105 90 110
1:4 Range 101-115 103-117 100-115
Average 107 110 108
1:8 Range 96-109 87-100 96-111
Average 102 93 104
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human ADAM10. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ADAM10 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ADAM10, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human ADAM10. You can calculate the concentration of Human ADAM10 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 102
Uniport ID O14672
Research Area Cancer , Cell Biology , Signal Transduction
Human ADAM10 (A Disintegrin And Metalloprotease 10) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}