Human ADRA1A (Adrenergic Receptor alpha-1A ) CLIA Kit (E-CL-H0229)

Human ADRA1A (Adrenergic Receptor alpha-1A ) CLIA Kit - 1
  • Human ADRA1A (Adrenergic Receptor alpha-1A ) CLIA Kit - 1
  • Human ADRA1A (Adrenergic Receptor alpha-1A ) CLIA Kit - 2
  • Human ADRA1A (Adrenergic Receptor alpha-1A ) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 37.5 pg/mL
Detection Range 62.5-4000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human ADRA1A in samples.No significant cross-reactivity or interference between Human ADRA1A and analogues was observed
Recovery 80%-120%
Sample Type Tissue homogenates, cell lysates and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
4000 61625.000 62015.000 61820.000 61783
2000 28619.000 30085.000 29352.000 29315
1000 15008.000 13832.000 14420.000 14383
500 6958.000 7554.000 7256.000 7219
250 3456.000 3122.000 3289.000 3252
125 1788.000 1672.000 1730.000 1693
62.5 751.000 817.000 784.000 747
0 36.000 38.000 37.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 185.440 371.170 1994.500 194.540 337.460 2101.720
Standard deviation 16.580 33.520 220.390 19.420 30.240 217.740
CV(%) 8.940 9.030 11.050 9.980 8.960 10.360
Recovery
The recovery of Human ADRA1A was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 98-111 105
EDTA plasma (n=8) 88-100 95
Cell culture media (n=8) 98-114 105
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human ADRA1A and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 86-100 85-95 101-113
Average 93 90 107
1:4 Range 90-106 96-113 97-112
Average 97 103 104
1:8 Range 88-100 96-110 89-100
Average 95 101 94
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human ADRA1A. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ADRA1A and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ADRA1A, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human ADRA1A. You can calculate the concentration of Human ADRA1A in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 148
Uniport ID P35348
Research Area Cancer , Cardiovascular , Neuroscience , Signal Transduction
Human ADRA1A (Adrenergic Receptor alpha-1A ) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定