Human AIF1 (Allograft Inflammatory Factor 1) CLIA Kit (E-CL-H0246)

Human AIF1 (Allograft Inflammatory Factor 1) CLIA Kit - 1
  • Human AIF1 (Allograft Inflammatory Factor 1) CLIA Kit - 1
  • Human AIF1 (Allograft Inflammatory Factor 1) CLIA Kit - 2
  • Human AIF1 (Allograft Inflammatory Factor 1) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 7.5 pg/mL
Detection Range 12.5-800 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human AIF1 in samples.No significant cross-reactivity or interference between Human AIF1 and analogues was observed
Recovery 80%-120%
Sample Type Tissue homogenates, cell lysates and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
800 54515.000 55903.000 55209.000 55183
400 21441.000 24379.000 22910.000 22884
200 10143.000 9275.000 9709.000 9683
100 4658.000 4728.000 4693.000 4667
50 2532.000 2166.000 2349.000 2323
25 1138.000 1038.000 1088.000 1062
12.5 546.000 556.000 551.000 525
0 26.000 26.000 26.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 37.450 82.230 389.360 40.070 85.450 384.980
Standard deviation 4.360 6.460 40.420 3.940 7.580 38.840
CV(%) 11.640 7.860 10.380 9.830 8.870 10.090
Recovery
The recovery of Human AIF1 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 89-102 95
EDTA plasma (n=8) 85-100 92
Cell culture media (n=8) 101-115 107
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human AIF1 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 84-96 86-99 99-111
Average 91 91 105
1:4 Range 90-101 100-114 88-101
Average 96 107 94
1:8 Range 93-105 85-97 94-108
Average 100 90 100
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human AIF1. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human AIF1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human AIF1, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human AIF1. You can calculate the concentration of Human AIF1 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 199
Uniport ID P55008
Research Area Cancer , Cell Biology , Metabolism , Immunology , Neuroscience
Human AIF1 (Allograft Inflammatory Factor 1) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定