Human AIF (Apoptosis Inducing Factor) CLIA Kit (E-CL-H0391)

Human AIF (Apoptosis Inducing Factor) CLIA Kit - 1
  • Human AIF (Apoptosis Inducing Factor) CLIA Kit - 1
  • Human AIF (Apoptosis Inducing Factor) CLIA Kit - 2
  • Human AIF (Apoptosis Inducing Factor) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 18.75 pg/mL
Detection Range 31.25-2000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human AIF in samples.No significant cross-reactivity or interference between Human AIF and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
2000 59030.000 62030.000 60530.000 60504
1000 24119.000 28407.000 26263.000 26237
500 12729.000 11257.000 11993.000 11967
250 5396.000 5406.000 5401.000 5375
125 2906.000 2810.000 2858.000 2832
62.5 1480.000 1310.000 1395.000 1369
31.25 706.000 754.000 730.000 704
0 25.000 27.000 26.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 95.600 250.840 948.150 102.820 227.580 911.560
Standard deviation 9.390 18.440 89.600 12.530 25.170 55.700
CV(%) 9.820 7.350 9.450 12.190 11.060 6.110
Recovery
The recovery of Human AIF was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 85-100 92
EDTA plasma (n=8) 93-104 98
Cell culture media (n=8) 85-97 91
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human AIF and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 94-106 94-109 100-118
Average 101 100 108
1:4 Range 96-109 86-100 88-99
Average 103 93 94
1:8 Range 99-114 91-106 88-100
Average 105 99 94
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human AIF. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human AIF and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human AIF, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human AIF. You can calculate the concentration of Human AIF in the samples by comparing the RLU value of the samples to the standard curve.
Human AIF (Apoptosis Inducing Factor) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定