Human AMPK (Phosphorylated Adenosine Monophosphate Activated Protein Kinase) CLIA Kit (E-CL-H0257)

Human AMPK (Phosphorylated Adenosine Monophosphate Activated Protein Kinase) CLIA Kit - 1
  • Human AMPK (Phosphorylated Adenosine Monophosphate Activated Protein Kinase) CLIA Kit - 1
  • Human AMPK (Phosphorylated Adenosine Monophosphate Activated Protein Kinase) CLIA Kit - 2
  • Human AMPK (Phosphorylated Adenosine Monophosphate Activated Protein Kinase) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 37.5 pg/mL
Detection Range 62.5-4000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human AMPK in samples.No significant cross-reactivity or interference between Human AMPK and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
4000 62217.000 63765.000 62991.000 62961
2000 26119.000 29953.000 28036.000 28006
1000 14559.000 14423.000 14491.000 14461
500 7028.000 7426.000 7227.000 7197
250 3750.000 3298.000 3524.000 3494
125 1720.000 1500.000 1610.000 1580
62.5 741.000 809.000 775.000 745
0 29.000 31.000 30.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 222.170 342.010 1651.960 238.780 369.060 1714.280
Standard deviation 18.880 27.090 179.070 21.370 42.040 196.800
CV(%) 8.500 7.920 10.840 8.950 11.390 11.480
Recovery
The recovery of Human AMPK was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 97-113 103
EDTA plasma (n=8) 90-104 98
Cell culture media (n=8) 89-99 94
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human AMPK and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 89-106 85-100 86-101
Average 97 92 93
1:4 Range 87-98 94-111 87-102
Average 93 101 93
1:8 Range 98-112 90-103 90-101
Average 106 97 95
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human AMPK. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human AMPK and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human AMPK, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human AMPK. You can calculate the concentration of Human AMPK in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 5562
Uniport ID Q13131
Research Area Cancer , Cardiovascular , Metabolism , Neuroscience , Signal Transduction
Human AMPK (Phosphorylated Adenosine Monophosphate Activated Protein Kinase) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.