Human ApoA1(Apolipoprotein A1) ELISA Kit

    • sandwich-Ab-ELISA-Elabscience
    • sandwich-Ab-ELISA-Elabscience
    • sandwich-Ab-ELISA-Elabscience
    <
    >
    • sandwich-Ab-ELISA-Elabscience
    • sandwich-Ab-ELISA-Elabscience
    • sandwich-Ab-ELISA-Elabscience
    • sandwich-Ab-ELISA-Elabscience
    • sandwich-Ab-ELISA-Elabscience
    • sandwich-Ab-ELISA-Elabscience

      Catalog number:E-EL-H0125

      Synonyms:APOA1, Apo-A1

      Size:
      • 96T
      • 24T
      Qty:
      - +
      Price: $495

      Reactivity: Human

      Detection Range: 3.13~200 ng/mL

      Sensitivity: 1.88 ng/mL

      Lead Time: 7~10 daysWelcome to order from local distributors.

      Add to cart Compare Bulk request

      Intended use

      This ELISA kit applies to the in vitro quantitative determination of Human ApoA1 concentrations in serum, plasma and other biological fluids.

      Test principle

      This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Human ApoA1. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ApoA1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ApoA1, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Human ApoA1. You can calculate the concentration of Human ApoA1 in the samples by comparing the OD of the samples to the standard curve.

      Assay type Sandwich
      Format 96T
      Assay time 3.5h
      Reactivity Human
      Detection Method Colormetric
      Detection Range 3.13—200 ng/mL
      Sensitivity 1.88 ng/mL
      Sample Volume Required Per Well 100μL
      Sample Type Serum, plasma and other biological fluids

      Specificity

      This kit recognizes Human ApoA1 in samples. No significant cross-reactivity or interference between Human ApoA1 and analogues was observed.

      Typical data

      As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.

      Concentration
      (ng/mL)
      O.D Average Corrected
      200 2.34
      2.396
      2.368 2.282
      100 1.582
      1.584
      1.583 1.497
      50 0.837
      0.829
      0.833 0.747
      25 0.409
      0.437
      0.423 0.337
      12.5 0.244
      0.218
      0.231 0.145
      6.25 0.187
      0.165
      0.176 0.09
      3.13 0.124
      0.142
      0.133 0.047
      0 0.079
      0.093
      0.086 --

      Precision

      Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Human ApoA1 were tested 20 times on one plate, respectively.
      Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Human ApoA1 were tested on 3 different plates, 20 replicates in each plate.

      Intra-assay Precision Inter-assay Precision
      Sample 1 2 3 1 2 3
      n 20 20 20 20 20 20
      Mean (ng/mL) 9.30 17.30 76.10 8.90 15.70 83.20
      Standard deviation 0.50 1.00 2.70 0.60 0.90 3.80
      C V (%) 5.38 5.78 3.55 6.74 5.73 4.57

      Recovery

      The recovery of Human ApoA1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

      Sample Type Range (%) Average Recovery (%)
      Serum (n=5) 93-105 98
      EDTA plasma (n=5) 85-96 91
      Cell culture media (n=5) 93-106 98

      Linearity

      Samples were spiked with high concentrations of Human ApoA1 and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.

      Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
      1:2 Range (%) 92-106 97-109 95-108
      Average (%) 97 103 101
      1:4 Range (%) 99-112 81-94 93-103
      Average (%) 107 87 98
      1:8 Range (%) 102-113 84-99 97-110
      Average (%) 107 90 103
      1:16 Range (%) 98-113 84-95 96-111
      Average (%) 105 90 101

      Kit components & Storage

      An unopened kit can be stored at 2-8°C for 1 month. If the kit is not used within 1 month, store the items separately according to the following conditions once the kit is received.

      Item Specifications Storage
      Micro ELISA Plate(Dismountable) 8 wells ×12 strips -20°C, 6 months
      Reference Standard 2 vials
      Concentrated Biotinylated Detection Ab (100×) 1 vial, 120 μL
      Concentrated HRP Conjugate (100×) 1 vial, 120 μL -20°C(shading light), 6 months
      Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
      Biotinylated Detection Ab Diluent 1 vial, 14 mL
      HRP Conjugate Diluent 1 vial, 14 mL
      Concentrated Wash Buffer (25×) 1 vial, 30 mL
      Substrate Reagent 1 vial, 10 mL 2-8°C(shading light)
      Stop Solution 1 vial, 10 mL 2-8°C
      Plate Sealer 5 pieces
      Product Description 1 copy
      Certificate of Analysis 1 copy

      Note: All reagent bottle caps must be tightened to prevent evaporation and microbial pollution.
      The volume of reagents in partial shipments is a little more than the volume marked on the label, please use accurate measuring equipment instead of directly pouring into the vial(s).

      Other supplies required

      • Microplate reader with 450 nm wavelength filter
      • High-precision transfer pipette, EP tubes and disposable pipette tips
      • Incubator capable of maintaining 37°C
      • Deionized or distilled water
      • Absorbent paper
      • Loading slot for Wash Buffer

      Assay Procedure

      elisa assay procedure 1

      1. Add 100μL standard or sample to the wells. Incubate for 90 min at 37°C

      elisa assay procedure 2

      2. Discard the liquid, immediately add 100μL Biotinylated Detection Ab working solution to each well. Incubate for 60 min at 37°C

      elisa assay procedure 3

      3. Aspirate and wash the plate for 3 times

      elisa assay procedure 4

      4. Add 100μL HRP conjugate working solution. Incubate for 30 min at 37°C. Aspirate and wash the plate for 5 times

      elisa assay procedure 5

      5. Add 90μL Substrate Reagent. Incubate for 15 min at 37°C

      elisa assay procedure 6

      6. Add 50μL Stop Solution

      elisa assay procedure 7

      7. Read the plate at 450nm immediately. Calculation of the results

      Citations

      1. Publication: Reddy M N, Dungdung R, Pilankatta R. Proteomic Analysis Reveals The Enhancement Of Human Serum Apolipoprotein A-1 (Apo A-1) In Individuals Infected With Multiple Dengue Virus Serotypes[J]. Tropical Medicine & International Health, 2017.
        Species: Human
        Sample Type: Serum
      • Show all (0)
      • Reviews (0)
      • Q&A (0)
      ... Show All Show Less
      MSDS for ELISA