Human ApoA2 (Apolipoprotein A2) CLIA Kit (E-CL-H0375)

Human ApoA2 (Apolipoprotein A2) CLIA Kit - 1
  • Human ApoA2 (Apolipoprotein A2) CLIA Kit - 1
  • Human ApoA2 (Apolipoprotein A2) CLIA Kit - 2
  • Human ApoA2 (Apolipoprotein A2) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 7.5 ng/mL
Detection Range 12.5-800 ng/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human ApoA2 in samples.No significant cross-reactivity or interference between Human ApoA2 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
ng/mL OD1 OD2 Mean OD Corrected OD
800 52715.000 61807.000 57261.000 57230
400 23028.000 24342.000 23685.000 23654
200 10414.000 9576.000 9995.000 9964
100 4547.000 4663.000 4605.000 4574
50 2463.000 2291.000 2377.000 2346
25 1161.000 1161.000 1161.000 1130
12.5 530.000 548.000 539.000 508
0 30.000 32.000 31.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(ng/mL) 40.910 68.230 364.550 38.060 74.450 354.800
Standard deviation 5.240 4.840 41.560 4.440 8.740 23.950
CV(%) 12.810 7.090 11.400 11.670 11.740 6.750
Recovery
The recovery of Human ApoA2 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 86-100 93
EDTA plasma (n=8) 89-100 94
Cell culture media (n=8) 96-109 103
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human ApoA2 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 88-100 85-99 91-103
Average 93 91 96
1:4 Range 102-115 101-114 96-111
Average 109 108 102
1:8 Range 86-100 88-103 92-103
Average 91 95 98
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human ApoA2. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ApoA2 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ApoA2, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human ApoA2. You can calculate the concentration of Human ApoA2 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 336
Uniport ID P02652
Research Area Cancer , Cardiovascular , Metabolism , Signal Transduction
Human ApoA2 (Apolipoprotein A2) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定