Human CDK6 (Cyclin Dependent Kinase 6) CLIA Kit (E-CL-H0254)

Human CDK6 (Cyclin Dependent Kinase 6) CLIA Kit - 1
  • Human CDK6 (Cyclin Dependent Kinase 6) CLIA Kit - 1
  • Human CDK6 (Cyclin Dependent Kinase 6) CLIA Kit - 2
  • Human CDK6 (Cyclin Dependent Kinase 6) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 18.75 pg/mL
Detection Range 31.25-2000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human CDK6 in samples.No significant cross-reactivity or interference between Human CDK6 and analogues was observed
Recovery 80%-120%
Sample Type Tissue homogenates, cell lysates and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
2000 51113.000 61547.000 56330.000 56305
1000 22534.000 25608.000 24071.000 24046
500 13147.000 11085.000 12116.000 12091
250 5006.000 5790.000 5398.000 5373
125 2963.000 2745.000 2854.000 2829
62.5 1391.000 1309.000 1350.000 1325
31.25 697.000 715.000 706.000 681
0 24.000 26.000 25.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 105.940 240.960 754.580 110.830 264.010 796.920
Standard deviation 12.250 27.880 73.270 10.570 21.360 85.030
CV(%) 11.560 11.570 9.710 9.540 8.090 10.670
Recovery
The recovery of Human CDK6 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 102-117 108
EDTA plasma (n=8) 101-115 107
Cell culture media (n=8) 87-97 92
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human CDK6 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 87-102 99-113 100-117
Average 94 104 106
1:4 Range 95-110 98-110 103-116
Average 101 104 110
1:8 Range 96-109 99-111 96-112
Average 102 105 102
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human CDK6. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CDK6 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CDK6, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human CDK6. You can calculate the concentration of Human CDK6 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 1021
Uniport ID Q00534
Research Area Cancer , Cell Biology , Epigenetics And Nuclear Signaling
Human CDK6 (Cyclin Dependent Kinase 6) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定