Human CDNF (Cerebral Dopamine Neurotrophic Factor) CLIA Kit (E-CL-H0276)

Human CDNF (Cerebral Dopamine Neurotrophic Factor) CLIA Kit - 1
  • Human CDNF (Cerebral Dopamine Neurotrophic Factor) CLIA Kit - 1
  • Human CDNF (Cerebral Dopamine Neurotrophic Factor) CLIA Kit - 2
  • Human CDNF (Cerebral Dopamine Neurotrophic Factor) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 18.75 pg/mL
Detection Range 31.25-2000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human CDNF in samples.No significant cross-reactivity or interference between Human CDNF and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
2000 59326.000 63058.000 61192.000 61160
1000 23914.000 24412.000 24163.000 24131
500 11264.000 11020.000 11142.000 11110
250 5077.000 5669.000 5373.000 5341
125 2741.000 2599.000 2670.000 2638
62.5 1487.000 1353.000 1420.000 1388
31.25 638.000 730.000 684.000 652
0 31.000 33.000 32.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 95.310 243.060 819.760 99.400 236.040 811.690
Standard deviation 8.700 19.150 60.250 12.640 21.550 90.260
CV(%) 9.130 7.880 7.350 12.720 9.130 11.120
Recovery
The recovery of Human CDNF was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 85-99 91
EDTA plasma (n=8) 95-112 103
Cell culture media (n=8) 86-102 93
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human CDNF and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 94-110 88-100 96-110
Average 100 93 104
1:4 Range 87-100 92-103 90-106
Average 94 98 96
1:8 Range 88-101 95-112 100-116
Average 95 102 109
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human CDNF. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CDNF and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CDNF, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human CDNF. You can calculate the concentration of Human CDNF in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 441549
Uniport ID Q49AH0
Research Area Neuroscience
Human CDNF (Cerebral Dopamine Neurotrophic Factor) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定