Human F9 (Coagulation Factor Ⅸ) CLIA Kit (E-CL-H0546)

Human F9 (Coagulation Factor Ⅸ) CLIA Kit - 1
  • Human F9 (Coagulation Factor Ⅸ) CLIA Kit - 1
  • Human F9 (Coagulation Factor Ⅸ) CLIA Kit - 2
  • Human F9 (Coagulation Factor Ⅸ) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 0.19 ng/mL
Detection Range 0.31-20 ng/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human F9 in samples.No significant cross-reactivity or interference between Human F9 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
ng/mL OD1 OD2 Mean OD Corrected OD
20 33140.000 36812.000 34976.000 34952
10 13006.000 13200.000 13103.000 13079
5 5589.000 5483.000 5536.000 5512
2.5 2515.000 2549.000 2532.000 2508
1.25 1583.000 1393.000 1488.000 1464
0.63 957.000 849.000 903.000 879
0.31 601.000 691.000 646.000 622
0 23.000 25.000 24.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(ng/mL) 0.960 1.990 8.480 0.970 2.090 8.920
Standard deviation 0.110 0.200 0.680 0.110 0.180 1.010
CV(%) 11.460 10.050 8.020 11.340 8.610 11.320
Recovery
The recovery of Human F9 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 93-107 99
EDTA plasma (n=8) 84-98 91
Cell culture media (n=8) 93-109 99
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human F9 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 88-102 99-113 98-112
Average 93 106 103
1:4 Range 91-103 86-97 89-104
Average 97 91 95
1:8 Range 93-105 90-101 99-118
Average 99 96 108
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human F9. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human F9 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human F9, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human F9. You can calculate the concentration of Human F9 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 2158
Uniport ID P00740
Research Area Cardiovascular , Immunology
Human F9 (Coagulation Factor Ⅸ) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定