Human FABP3 (Fatty Acid Binding Protein 3, Muscle and Heart) CLIA Kit (E-CL-H0919)

Human FABP3 (Fatty Acid Binding Protein 3, Muscle and Heart) CLIA Kit - 1
  • Human FABP3 (Fatty Acid Binding Protein 3, Muscle and Heart) CLIA Kit - 1
  • Human FABP3 (Fatty Acid Binding Protein 3, Muscle and Heart) CLIA Kit - 2
  • Human FABP3 (Fatty Acid Binding Protein 3, Muscle and Heart) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 18.75 pg/mL
Detection Range 31.25-2000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human FABP3 in samples.No significant cross-reactivity or interference between Human FABP3 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
2000 53884.000 63478.000 58681.000 58649
1000 23737.000 27799.000 25768.000 25736
500 12023.000 10591.000 11307.000 11275
250 5443.000 5621.000 5532.000 5500
125 2870.000 2792.000 2831.000 2799
62.5 1410.000 1400.000 1405.000 1373
31.25 636.000 714.000 675.000 643
0 31.000 33.000 32.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 102.640 225.200 728.630 93.930 228.990 730.080
Standard deviation 9.670 15.760 83.570 11.670 23.700 78.630
CV(%) 9.420 7.000 11.470 12.420 10.350 10.770
Recovery
The recovery of Human FABP3 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 97-111 105
EDTA plasma (n=8) 98-115 105
Cell culture media (n=8) 98-113 104
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human FABP3 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 87-100 88-101 90-104
Average 94 96 96
1:4 Range 88-104 89-104 93-103
Average 95 96 98
1:8 Range 89-103 97-111 94-110
Average 94 104 101
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human FABP3. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human FABP3 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human FABP3, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human FABP3. You can calculate the concentration of Human FABP3 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 2170
Uniport ID P05413
Research Area Cancer , Cardiovascular , Metabolism , Stem Cells
Human FABP3 (Fatty Acid Binding Protein 3, Muscle and Heart) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定