Human Fcγ (Fc Fragment of IgG) CLIA Kit (E-CL-H1091)

Human Fcγ (Fc Fragment of IgG) CLIA Kit - 1
  • Human Fcγ (Fc Fragment of IgG) CLIA Kit - 1
  • Human Fcγ (Fc Fragment of IgG) CLIA Kit - 2
  • Human Fcγ (Fc Fragment of IgG) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 37.5 pg/mL
Detection Range 62.5-4000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human Fcγ in samples.No significant cross-reactivity or interference between Human Fcγ and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
4000 62006.000 67954.000 64980.000 64948
2000 26799.000 31639.000 29219.000 29187
1000 14775.000 14543.000 14659.000 14627
500 6380.000 6934.000 6657.000 6625
250 3614.000 3152.000 3383.000 3351
125 1824.000 1610.000 1717.000 1685
62.5 717.000 817.000 767.000 735
0 32.000 32.000 32.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 186.670 381.240 1992.210 183.210 395.080 2189.280
Standard deviation 17.490 30.650 148.220 20.720 34.930 143.840
CV(%) 9.370 8.040 7.440 11.310 8.840 6.570
Recovery
The recovery of Human Fcγ was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 88-103 96
EDTA plasma (n=8) 99-113 105
Cell culture media (n=8) 87-101 94
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human Fcγ and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 87-100 102-114 97-114
Average 94 108 104
1:4 Range 98-115 98-114 104-117
Average 106 106 110
1:8 Range 89-102 90-107 100-115
Average 94 97 105
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human Fcγ. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human Fcγ and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human Fcγ, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human Fcγ. You can calculate the concentration of Human Fcγ in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 7083
Uniport ID P01857 P01859 P01860 P01861
Research Area Immunology
Human Fcγ (Fc Fragment of IgG) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定