Human MYL9 (Myosin Light Chain 9, Regulatory) CLIA Kit (E-CL-H0524)

Human MYL9 (Myosin Light Chain 9, Regulatory) CLIA Kit - 1
  • Human MYL9 (Myosin Light Chain 9, Regulatory) CLIA Kit - 1
  • Human MYL9 (Myosin Light Chain 9, Regulatory) CLIA Kit - 2
  • Human MYL9 (Myosin Light Chain 9, Regulatory) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 9.38 pg/mL
Detection Range 15.63-1000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human MYL9 in samples.No significant cross-reactivity or interference between Human MYL9 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
1000 57852.000 58966.000 58409.000 58376
500 21933.000 23577.000 22755.000 22722
250 11629.000 10139.000 10884.000 10851
125 5294.000 5430.000 5362.000 5329
62.5 2756.000 2380.000 2568.000 2535
31.25 1421.000 1223.000 1322.000 1289
15.63 718.000 756.000 737.000 704
0 32.000 34.000 33.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 51.790 84.090 372.030 48.620 89.880 400.180
Standard deviation 5.960 6.250 27.120 5.840 8.390 38.100
CV(%) 11.510 7.430 7.290 12.010 9.330 9.520
Recovery
The recovery of Human MYL9 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 93-108 100
EDTA plasma (n=8) 89-102 94
Cell culture media (n=8) 97-112 104
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human MYL9 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 87-98 93-110 98-113
Average 92 100 103
1:4 Range 84-97 100-116 86-100
Average 90 106 92
1:8 Range 95-110 94-109 95-108
Average 101 99 101
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human MYL9. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human MYL9 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human MYL9, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human MYL9. You can calculate the concentration of Human MYL9 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 10398
Uniport ID P24844
Research Area Cancer , Cardiovascular , Signaltransduction , Stemcells
Human MYL9 (Myosin Light Chain 9, Regulatory) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定