Human NE/ELA2 (Elastase 2, Neutrophil) CLIA Kit (E-CL-H1196)

Human NE/ELA2 (Elastase 2, Neutrophil) CLIA Kit - 1
  • Human NE/ELA2 (Elastase 2, Neutrophil) CLIA Kit - 1
  • Human NE/ELA2 (Elastase 2, Neutrophil) CLIA Kit - 2
  • Human NE/ELA2 (Elastase 2, Neutrophil) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 0.09 ng/mL
Detection Range 0.16-10 ng/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human NE/ELA2 in samples.No significant cross-reactivity or interference between Human NE/ELA2 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
ng/mL OD1 OD2 Mean OD Corrected OD
10 31802.000 37874.000 34838.000 34808
5 15533.000 16675.000 16104.000 16074
2.5 7843.000 7785.000 7814.000 7784
1.25 3768.000 3902.000 3835.000 3805
0.63 1884.000 1878.000 1881.000 1851
0.31 938.000 822.000 880.000 850
0.16 347.000 371.000 359.000 329
0 30.000 30.000 30.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(ng/mL) 0.480 1.150 4.330 0.490 1.210 4.410
Standard deviation 0.040 0.090 0.270 0.050 0.090 0.410
CV(%) 8.330 7.830 6.240 10.200 7.440 9.300
Recovery
The recovery of Human NE was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 95-108 103
EDTA plasma (n=8) 97-111 102
Cell culture media (n=8) 98-112 104
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human NE and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 90-104 98-115 86-97
Average 97 105 92
1:4 Range 89-101 84-99 93-106
Average 94 91 99
1:8 Range 99-117 101-117 102-116
Average 107 109 108
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human NE/ELA2. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human NE/ELA2 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human NE/ELA2, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human NE/ELA2. You can calculate the concentration of Human NE/ELA2 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 1991
Uniport ID P08246
Research Area Cancer , Immunology , Microbiology , Signaltransduction
Human NE/ELA2 (Elastase 2, Neutrophil) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}