Human PAP (Plasmin-Antiplasmin Complex) CLIA Kit (E-CL-H1259)

Human PAP (Plasmin-Antiplasmin Complex) CLIA Kit - 1
  • Human PAP (Plasmin-Antiplasmin Complex) CLIA Kit - 1
  • Human PAP (Plasmin-Antiplasmin Complex) CLIA Kit - 2
  • Human PAP (Plasmin-Antiplasmin Complex) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 0.38 ng/mL
Detection Range 0.63-40 ng/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human PAP in samples.No significant cross-reactivity or interference between Human PAP and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
ng/mL OD1 OD2 Mean OD Corrected OD
40 39219.000 40697.000 39958.000 39923
20 14697.000 16045.000 15371.000 15336
10 6845.000 6349.000 6597.000 6562
5 3025.000 3171.000 3098.000 3063
2.5 1723.000 1469.000 1596.000 1561
1.25 1025.000 877.000 951.000 916
0.63 570.000 626.000 598.000 563
0 34.000 36.000 35.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(ng/mL) 1.950 4.760 13.910 2.080 4.820 12.890
Standard deviation 0.220 0.430 0.860 0.190 0.380 0.910
CV(%) 11.280 9.030 6.180 9.130 7.880 7.060
Recovery
The recovery of Human PAP was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 93-109 99
EDTA plasma (n=8) 92-108 99
Cell culture media (n=8) 90-102 96
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human PAP and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 85-101 98-113 87-98
Average 92 106 92
1:4 Range 87-100 89-102 91-104
Average 94 96 96
1:8 Range 92-106 88-102 97-111
Average 99 95 103
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human PAP. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human PAP and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human PAP, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human PAP. You can calculate the concentration of Human PAP in the samples by comparing the RLU value of the samples to the standard curve.
Research Area Tags&CellMarkers , CellBiology , Cancer
Human PAP (Plasmin-Antiplasmin Complex) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定