Human S100A11 (S100 Calcium Binding Protein A11) CLIA Kit (E-CL-H0843)

Human S100A11 (S100 Calcium Binding Protein A11) CLIA Kit - 1
  • Human S100A11 (S100 Calcium Binding Protein A11) CLIA Kit - 1
  • Human S100A11 (S100 Calcium Binding Protein A11) CLIA Kit - 2
  • Human S100A11 (S100 Calcium Binding Protein A11) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 37.5 pg/mL
Detection Range 62.5-4000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human S100A11 in samples.No significant cross-reactivity or interference between Human S100A11 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
4000 56747.000 66201.000 61474.000 61434
2000 28827.000 32215.000 30521.000 30481
1000 14569.000 14197.000 14383.000 14343
500 6763.000 7051.000 6907.000 6867
250 3638.000 3428.000 3533.000 3493
125 1839.000 1633.000 1736.000 1696
62.5 769.000 821.000 795.000 755
0 39.000 41.000 40.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 218.130 537.350 1645.330 238.260 510.960 1712.520
Standard deviation 21.970 56.800 148.410 27.230 40.060 132.720
CV(%) 10.070 10.570 9.020 11.430 7.840 7.750
Recovery
The recovery of Human S100A11 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 96-109 102
EDTA plasma (n=8) 91-106 99
Cell culture media (n=8) 93-107 101
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human S100A11 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 85-99 85-97 99-115
Average 91 92 105
1:4 Range 93-103 94-107 95-108
Average 98 101 101
1:8 Range 94-108 86-102 93-109
Average 102 93 99
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human S100A11. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human S100A11 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human S100A11, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human S100A11. You can calculate the concentration of Human S100A11 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 6282
Uniport ID P31949
Research Area Cancer , CellBiology , Signaltransduction
Human S100A11 (S100 Calcium Binding Protein A11) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定