Mouse AhR (Aryl Hydrocarbon Receptor) CLIA Kit (E-CL-M0117)

Mouse AhR (Aryl Hydrocarbon Receptor) CLIA Kit - 1
  • Mouse AhR (Aryl Hydrocarbon Receptor) CLIA Kit - 1
  • Mouse AhR (Aryl Hydrocarbon Receptor) CLIA Kit - 2
  • Mouse AhR (Aryl Hydrocarbon Receptor) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 46.88 pg/mL
Detection Range 78.13-5000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Mouse
Specificity This kit recognizes Mouse AhR in samples.No significant cross-reactivity or interference between Mouse AhR and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
5000 58119.000 64977.000 61548.000 61517
2500 32341.000 39023.000 35682.000 35651
1250 19897.000 16945.000 18421.000 18390
625 9303.000 10745.000 10024.000 9993
312.5 5446.000 5110.000 5278.000 5247
156.25 2779.000 2437.000 2608.000 2577
78.13 1340.000 1446.000 1393.000 1362
0 30.000 32.000 31.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 239.730 772.250 2273.220 236.890 830.970 2346.550
Standard deviation 28.260 65.870 218.230 24.780 59.330 269.620
CV(%) 11.790 8.530 9.600 10.460 7.140 11.490
Recovery
The recovery of Mouse AhR was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 88-99 93
EDTA plasma (n=8) 94-105 100
Cell culture media (n=8) 99-112 107
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Mouse AhR and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 94-109 84-96 100-115
Average 101 90 107
1:4 Range 102-119 95-109 100-115
Average 110 102 106
1:8 Range 87-98 99-115 86-98
Average 92 107 91
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Mouse AhR. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse AhR and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse AhR, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Mouse AhR. You can calculate the concentration of Mouse AhR in the samples by comparing the RLU value of the samples to the standard curve.
Uniport ID P30561
Research Area Cancer , EpigeneticsandNuclearSignaling
Mouse AhR (Aryl Hydrocarbon Receptor) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定