Mouse ERα (Estrogen Receptor Alpha) CLIA Kit (E-CL-M0289)

Mouse ERα (Estrogen Receptor Alpha) CLIA Kit - 1
  • Mouse ERα (Estrogen Receptor Alpha) CLIA Kit - 1
  • Mouse ERα (Estrogen Receptor Alpha) CLIA Kit - 2
  • Mouse ERα (Estrogen Receptor Alpha) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 37.5 pg/mL
Detection Range 62.5-4000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Mouse
Specificity This kit recognizes Mouse ERα in samples.No significant cross-reactivity or interference between Mouse ERα and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
4000 57220.000 65878.000 61549.000 61516
2000 27648.000 32050.000 29849.000 29816
1000 15469.000 13951.000 14710.000 14677
500 7100.000 7298.000 7199.000 7166
250 3599.000 3225.000 3412.000 3379
125 1706.000 1698.000 1702.000 1669
62.5 771.000 879.000 825.000 792
0 32.000 34.000 33.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 192.860 518.670 1894.660 178.390 525.640 1866.660
Standard deviation 19.420 46.210 143.990 16.300 47.410 213.170
CV(%) 10.070 8.910 7.600 9.140 9.020 11.420
Recovery
The recovery of Mouse ERα was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 94-107 101
EDTA plasma (n=8) 91-104 97
Cell culture media (n=8) 86-97 91
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Mouse ERα and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 97-113 85-98 94-109
Average 104 91 100
1:4 Range 90-103 99-117 91-105
Average 97 107 99
1:8 Range 99-114 86-101 93-110
Average 106 92 100
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Mouse ERα. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse ERα and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse ERα, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Mouse ERα. You can calculate the concentration of Mouse ERα in the samples by comparing the RLU value of the samples to the standard curve.
Mouse ERα (Estrogen Receptor Alpha) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定