Mouse F12 (Coagulation Factor Ⅻ) CLIA Kit (E-CL-M0209)

Mouse F12 (Coagulation Factor Ⅻ) CLIA Kit - 1
  • Mouse F12 (Coagulation Factor Ⅻ) CLIA Kit - 1
  • Mouse F12 (Coagulation Factor Ⅻ) CLIA Kit - 2
  • Mouse F12 (Coagulation Factor Ⅻ) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 18.75 pg/mL
Detection Range 31.25-2000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Mouse
Specificity This kit recognizes Mouse F12 in samples.No significant cross-reactivity or interference between Mouse F12 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
2000 55671.000 65437.000 60554.000 60514
1000 22816.000 26814.000 24815.000 24775
500 11995.000 10951.000 11473.000 11433
250 5284.000 5886.000 5585.000 5545
125 2837.000 2473.000 2655.000 2615
62.5 1358.000 1294.000 1326.000 1286
31.25 690.000 698.000 694.000 654
0 40.000 40.000 40.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 100.160 183.720 730.370 104.630 179.230 800.530
Standard deviation 9.580 19.930 45.870 12.310 16.240 69.890
CV(%) 9.560 10.850 6.280 11.770 9.060 8.730
Recovery
The recovery of Mouse F12 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 94-109 101
EDTA plasma (n=8) 86-98 91
Cell culture media (n=8) 84-95 90
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Mouse F12 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 88-100 100-118 100-112
Average 93 108 107
1:4 Range 89-99 99-116 99-115
Average 94 107 105
1:8 Range 87-98 91-105 90-104
Average 93 97 98
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Mouse F12. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse F12 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse F12, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Mouse F12. You can calculate the concentration of Mouse F12 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 58992
Uniport ID Q80YC5
Research Area Cancer , Cardiovascular
Mouse F12 (Coagulation Factor Ⅻ) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定