Mouse GH (Growth Hormone) CLIA Kit (E-CL-M0054)

Mouse GH (Growth Hormone) CLIA Kit - 1
  • Mouse GH (Growth Hormone) CLIA Kit - 1
  • Mouse GH (Growth Hormone) CLIA Kit - 2
  • Mouse GH (Growth Hormone) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 37.5 pg/mL
Detection Range 62.5-4000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Mouse
Specificity This kit recognizes Mouse GH in samples.No significant cross-reactivity or interference between Mouse GH and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
4000 58191.000 66251.000 62221.000 62179
2000 26432.000 30178.000 28305.000 28263
1000 14956.000 13102.000 14029.000 13987
500 6598.000 7852.000 7225.000 7183
250 3755.000 3313.000 3534.000 3492
125 1774.000 1566.000 1670.000 1628
62.5 786.000 864.000 825.000 783
0 42.000 42.000 42.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 203.340 608.150 1950.460 186.320 551.640 1807.140
Standard deviation 22.900 72.550 163.250 18.840 52.520 159.030
CV(%) 11.260 11.930 8.370 10.110 9.520 8.800
Recovery
The recovery of Mouse GH was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 93-108 101
EDTA plasma (n=8) 86-96 91
Cell culture media (n=8) 98-111 104
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Mouse GH and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 94-108 91-108 85-97
Average 102 98 91
1:4 Range 99-117 94-105 100-117
Average 107 99 109
1:8 Range 96-113 87-98 86-98
Average 104 93 92
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Mouse GH. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse GH and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse GH, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Mouse GH. You can calculate the concentration of Mouse GH in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 14599
Uniport ID P06880
Research Area Cancer , Developmental Biology , Signal Transduction
Mouse GH (Growth Hormone) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定