Mouse MHCI/H-2Ⅰ(Major Histocompatibility ComplexⅠ) CLIA Kit (E-CL-M0489)

Mouse MHCI/H-2Ⅰ(Major Histocompatibility ComplexⅠ) CLIA Kit - 1
  • Mouse MHCI/H-2Ⅰ(Major Histocompatibility ComplexⅠ) CLIA Kit - 1
  • Mouse MHCI/H-2Ⅰ(Major Histocompatibility ComplexⅠ) CLIA Kit - 2
  • Mouse MHCI/H-2Ⅰ(Major Histocompatibility ComplexⅠ) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 1.88 pg/mL
Detection Range 3.13-200 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Mouse
Specificity This kit recognizes Mouse MHCⅠ/H-2Ⅰ in samples.No significant cross-reactivity or interference between Mouse MHCⅠ/H-2Ⅰ and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
200 46247.000 49053.000 47650.000 47617
100 17874.000 18944.000 18409.000 18376
50 9313.000 7869.000 8591.000 8558
25 3833.000 4121.000 3977.000 3944
12.5 2008.000 1970.000 1989.000 1956
6.25 1120.000 1062.000 1091.000 1058
3.13 574.000 636.000 605.000 572
0 32.000 34.000 33.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 9.880 26.070 90.280 9.280 28.380 91.720
Standard deviation 1.130 2.240 9.660 0.990 2.840 7.030
CV(%) 11.440 8.590 10.700 10.670 10.010 7.660
Recovery
The recovery of Mouse MHCI/H-2Ⅰ was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 92-106 98
EDTA plasma (n=8) 89-102 96
Cell culture media (n=8) 91-105 96
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Mouse MHCI/H-2Ⅰ and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 91-106 100-117 91-101
Average 98 107 96
1:4 Range 93-109 89-104 100-112
Average 99 95 106
1:8 Range 100-114 101-114 94-107
Average 107 108 99
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Mouse MHCⅠ/H-2Ⅰ. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse MHCⅠ/H-2Ⅰ and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse MHCⅠ/H-2Ⅰ, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Mouse MHCⅠ/H-2Ⅰ. You can calculate the concentration of Mouse MHCⅠ/H-2Ⅰ in the samples by comparing the RLU value of the samples to the standard curve.
Research Area Immunology , Microbiology
Mouse MHCI/H-2Ⅰ(Major Histocompatibility ComplexⅠ) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定