Mouse VEGF-C (Vascular Endothelial cell Growth Factor C) CLIA Kit (E-CL-M0679)

Mouse VEGF-C (Vascular Endothelial cell Growth Factor C) CLIA Kit - 1
  • Mouse VEGF-C (Vascular Endothelial cell Growth Factor C) CLIA Kit - 1
  • Mouse VEGF-C (Vascular Endothelial cell Growth Factor C) CLIA Kit - 2
  • Mouse VEGF-C (Vascular Endothelial cell Growth Factor C) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 7.5 pg/mL
Detection Range 12.5-800 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Mouse
Specificity This kit recognizes Mouse VEGF-C in samples.No significant cross-reactivity or interference between Mouse VEGF-C and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
800 52462.000 53142.000 52802.000 52767
400 20338.000 24606.000 22472.000 22437
200 11305.000 9881.000 10593.000 10558
100 4477.000 5353.000 4915.000 4880
50 2489.000 2135.000 2312.000 2277
25 1193.000 1035.000 1114.000 1079
12.5 527.000 563.000 545.000 510
0 35.000 35.000 35.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 39.370 120.900 399.970 37.990 117.060 400.990
Standard deviation 4.650 13.790 27.520 4.110 12.030 33.200
CV(%) 11.810 11.410 6.880 10.820 10.280 8.280
Recovery
The recovery of Mouse VEGF-C was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 95-107 100
EDTA plasma (n=8) 89-104 97
Cell culture media (n=8) 85-95 90
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Mouse VEGF-C and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 95-113 101-115 101-118
Average 103 107 109
1:4 Range 103-120 91-105 99-116
Average 109 96 107
1:8 Range 94-109 93-106 85-97
Average 101 99 90
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Mouse VEGF-C. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse VEGF-C and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse VEGF-C, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Mouse VEGF-C. You can calculate the concentration of Mouse VEGF-C in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 22341
Uniport ID P97953
Research Area Cancer , Cardiovascular , Neuroscience , Signal Transduction
Mouse VEGF-C (Vascular Endothelial cell Growth Factor C) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定