Rat AMPK (Phosphorylated Adenosine Monophosphate Activated Protein Kinase) CLIA Kit (E-CL-R0517)

Rat AMPK (Phosphorylated Adenosine Monophosphate Activated Protein Kinase) CLIA Kit - 1
  • Rat AMPK (Phosphorylated Adenosine Monophosphate Activated Protein Kinase) CLIA Kit - 1
  • Rat AMPK (Phosphorylated Adenosine Monophosphate Activated Protein Kinase) CLIA Kit - 2
  • Rat AMPK (Phosphorylated Adenosine Monophosphate Activated Protein Kinase) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 0.38 ng/mL
Detection Range 0.63-40 ng/mL
Sample Volume 100 μL
Total Assay Time 4 h 30 min
Reactivity Rat
Specificity This kit recognizes Rat AMPK in samples.No significant cross-reactivity or interference between Rat AMPK and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
ng/mL OD1 OD2 Mean OD Corrected OD
40 36412.000 39576.000 37994.000 37959
20 13111.000 16003.000 14557.000 14522
10 6893.000 6165.000 6529.000 6494
5 3052.000 3166.000 3109.000 3074
2.5 1623.000 1575.000 1599.000 1564
1.25 1070.000 934.000 1002.000 967
0.63 606.000 678.000 642.000 607
0 33.000 37.000 35.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(ng/mL) 1.930 3.940 19.620 1.800 3.910 20.810
Standard deviation 0.220 0.390 1.190 0.220 0.450 1.790
CV(%) 11.400 9.900 6.070 12.220 11.510 8.600
Recovery
The recovery of Rat AMPK was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 101-115 107
EDTA plasma (n=8) 88-100 93
Cell culture media (n=8) 89-103 96
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Rat AMPK and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 83-97 96-111 85-99
Average 90 103 91
1:4 Range 103-116 99-114 85-101
Average 109 107 92
1:8 Range 103-116 99-115 102-115
Average 110 105 108
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Rat AMPK. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat AMPK and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat AMPK, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Rat AMPK. You can calculate the concentration of Rat AMPK in the samples by comparing the RLU value of the samples to the standard curve.
Rat AMPK (Phosphorylated Adenosine Monophosphate Activated Protein Kinase) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定