Rat HSP-90 (Heat Shock Protein 90) CLIA Kit (E-CL-R0327)

Rat HSP-90 (Heat Shock Protein 90) CLIA Kit - 1
  • Rat HSP-90 (Heat Shock Protein 90) CLIA Kit - 1
  • Rat HSP-90 (Heat Shock Protein 90) CLIA Kit - 2
  • Rat HSP-90 (Heat Shock Protein 90) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 18.75 pg/mL
Detection Range 31.25-2000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Rat
Specificity This kit recognizes Rat HSP-90 in samples.No significant cross-reactivity or interference between Rat HSP-90 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
2000 58774.000 58846.000 58810.000 58785
1000 22846.000 27232.000 25039.000 25014
500 12355.000 11439.000 11897.000 11872
250 5181.000 5697.000 5439.000 5414
125 2970.000 2686.000 2828.000 2803
62.5 1470.000 1266.000 1368.000 1343
31.25 665.000 739.000 702.000 677
0 24.000 26.000 25.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 97.840 171.970 837.390 105.440 163.680 900.900
Standard deviation 8.900 17.400 53.680 12.470 16.970 93.510
CV(%) 9.100 10.120 6.410 11.830 10.370 10.380
Recovery
The recovery of Rat HSP-90 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 85-97 90
EDTA plasma (n=8) 96-110 102
Cell culture media (n=8) 98-110 104
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Rat HSP-90 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 91-108 95-108 86-102
Average 98 101 93
1:4 Range 93-106 90-105 94-110
Average 98 98 102
1:8 Range 99-110 96-112 94-111
Average 104 103 101
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Rat HSP-90. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat HSP-90 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat HSP-90, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Rat HSP-90. You can calculate the concentration of Rat HSP-90 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 299331, 301252
Uniport ID P82995 P34058
Research Area Cancer , Signaltransduction
Rat HSP-90 (Heat Shock Protein 90) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定