Rat IGF-1 (Insulin-Like Growth Factor 1) CLIA Kit (E-CL-R0010)

Rat IGF-1 (Insulin-Like Growth Factor 1) CLIA Kit - 1
  • Rat IGF-1 (Insulin-Like Growth Factor 1) CLIA Kit - 1
  • Rat IGF-1 (Insulin-Like Growth Factor 1) CLIA Kit - 2
  • Rat IGF-1 (Insulin-Like Growth Factor 1) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 7.5 pg/mL
Detection Range 12.5-800 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Rat
Specificity This kit recognizes Rat IGF-1 in samples.No significant cross-reactivity or interference between Rat IGF-1 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
800 57344.000 58440.000 57892.000 57865
400 22946.000 23956.000 23451.000 23424
200 10948.000 9944.000 10446.000 10419
100 4570.000 5344.000 4957.000 4930
50 2261.000 2241.000 2251.000 2224
25 1170.000 1156.000 1163.000 1136
12.5 517.000 577.000 547.000 520
0 26.000 28.000 27.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 39.760 95.950 349.430 42.960 98.560 338.710
Standard deviation 3.840 11.030 36.790 3.810 7.270 23.910
CV(%) 9.660 11.500 10.530 8.870 7.380 7.060
Recovery
The recovery of Rat IGF-1 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 89-102 94
EDTA plasma (n=8) 93-107 99
Cell culture media (n=8) 97-109 104
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Rat IGF-1 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 91-103 90-105 95-109
Average 96 97 101
1:4 Range 93-106 92-104 86-97
Average 100 97 91
1:8 Range 97-110 91-103 86-100
Average 103 97 91
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Rat IGF-1. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat IGF-1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat IGF-1, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Rat IGF-1. You can calculate the concentration of Rat IGF-1 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 24482
Uniport ID P08025
Research Area Cancer , Developmental Biology , Signal Transduction
Rat IGF-1 (Insulin-Like Growth Factor 1) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定