Facebook

All categories

  • All categories
  • Flow Cytometry Antibodies
  • Immunoassays
  • Antibodies and Reagents
  • Cell Identification Kits
  • Cell Isolation Products
  • Cell Health and Metabolism Assay Kits
  • Proteins and Peptides
  • Cell Culture
Please enter the item number/product keyword!
Keyword cannot be empty !
INSERT SYMBOLS:
  • α
  • β
  • γ
  • δ
  • ε
  • ζ
  • η
  • θ
  • κ
  • μ
  • ω
  • σ
  • τ
  • λ
  • ⅩⅢ
  • ⅩⅢ
  • ⅩⅣ
  • ⅩⅤ
  • ⅩⅦ
  • ⅩⅧ
  • UP ↑

Rat INSR-β (Insulin Receptor Beta Subunit) CLIA Kit (E-CL-R0366)

Rat INSR-β (Insulin Receptor Beta Subunit) CLIA Kit - 1
  • Rat INSR-β (Insulin Receptor Beta Subunit) CLIA Kit - 1
  • Rat INSR-β (Insulin Receptor Beta Subunit) CLIA Kit - 2
  • Rat INSR-β (Insulin Receptor Beta Subunit) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 0.09 ng/mL
Detection Range 0.16-10 ng/mL
Sample Volume 100 μL
Total Assay Time 4 h 30 min
Reactivity Rat
Specificity This kit recognizes Rat INSR-β in samples.No significant cross-reactivity or interference between Rat INSR-β and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
ng/mL OD1 OD2 Mean OD Corrected OD
10 34601.000 36301.000 35451.000 35416
5 15820.000 16514.000 16167.000 16132
2.5 8148.000 7612.000 7880.000 7845
1.25 3829.000 3961.000 3895.000 3860
0.63 1874.000 1762.000 1818.000 1783
0.31 918.000 864.000 891.000 856
0.16 374.000 408.000 391.000 356
0 33.000 37.000 35.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(ng/mL) 0.510 0.950 4.760 0.500 0.870 4.580
Standard deviation 0.060 0.070 0.530 0.050 0.080 0.420
CV(%) 11.760 7.370 11.130 10.000 9.200 9.170
Recovery
The recovery of Rat INSR-β was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 91-103 96
EDTA plasma (n=8) 92-107 99
Cell culture media (n=8) 102-114 108
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Rat INSR-β and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 99-111 99-113 97-108
Average 105 107 103
1:4 Range 87-99 97-111 87-103
Average 92 103 94
1:8 Range 88-100 95-109 95-112
Average 95 102 103
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Rat INSR-β. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat INSR-β and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat INSR-β, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Rat INSR-β. You can calculate the concentration of Rat INSR-β in the samples by comparing the RLU value of the samples to the standard curve.
Rat INSR-β (Insulin Receptor Beta Subunit) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定