Human ABCG1 (ATP Binding Cassette Transporter G1) CLIA Kit (E-CL-H0423)

Human ABCG1 (ATP Binding Cassette Transporter G1) CLIA Kit - 1
  • Human ABCG1 (ATP Binding Cassette Transporter G1) CLIA Kit - 1
  • Human ABCG1 (ATP Binding Cassette Transporter G1) CLIA Kit - 2
  • Human ABCG1 (ATP Binding Cassette Transporter G1) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 18.75 pg/mL
Detection Range 31.25-2000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human ABCG1 in samples.No significant cross-reactivity or interference between Human ABCG1 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
2000 51688.000 61580.000 56634.000 56605
1000 23666.000 27804.000 25735.000 25706
500 11610.000 11170.000 11390.000 11361
250 5336.000 6026.000 5681.000 5652
125 3000.000 2628.000 2814.000 2785
62.5 1442.000 1244.000 1343.000 1314
31.25 690.000 758.000 724.000 695
0 29.000 29.000 29.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 98.360 258.810 673.220 101.870 238.810 618.160
Standard deviation 8.560 25.910 50.760 12.470 27.100 43.460
CV(%) 8.700 10.010 7.540 12.240 11.350 7.030
Recovery
The recovery of Human ABCG1 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 89-101 94
EDTA plasma (n=8) 87-101 93
Cell culture media (n=8) 85-98 90
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human ABCG1 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 89-105 93-108 89-104
Average 96 99 96
1:4 Range 96-114 98-113 91-106
Average 104 105 97
1:8 Range 86-101 89-100 98-114
Average 93 94 104
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human ABCG1. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ABCG1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ABCG1, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human ABCG1. You can calculate the concentration of Human ABCG1 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 9619
Uniport ID P45844
Research Area Cancer , Cardiovascular , Metabolism , Neuroscience , Signal Transduction
Human ABCG1 (ATP Binding Cassette Transporter G1) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定