Human ADH1 (Alcohol Dehydrogenase 1) CLIA Kit (E-CL-H0224)

Human ADH1 (Alcohol Dehydrogenase 1) CLIA Kit - 1
  • Human ADH1 (Alcohol Dehydrogenase 1) CLIA Kit - 1
  • Human ADH1 (Alcohol Dehydrogenase 1) CLIA Kit - 2
  • Human ADH1 (Alcohol Dehydrogenase 1) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 18.75 pg/mL
Detection Range 31.25-2000 pg/mL
Sample Volume 100 μL
Total Assay Time 4 h 30 min
Reactivity Human
Specificity This kit recognizes Human ADH1 in samples.No significant cross-reactivity or interference between Human ADH1 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
2000 53622.000 64368.000 58995.000 58959
1000 23835.000 24781.000 24308.000 24272
500 12182.000 10210.000 11196.000 11160
250 5394.000 6054.000 5724.000 5688
125 3017.000 2579.000 2798.000 2762
62.5 1346.000 1294.000 1320.000 1284
31.25 721.000 751.000 736.000 700
0 35.000 37.000 36.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 110.360 168.840 853.180 112.710 173.880 870.220
Standard deviation 13.640 13.710 78.320 14.440 17.940 64.140
CV(%) 12.360 8.120 9.180 12.810 10.320 7.370
Recovery
The recovery of Human ADH1 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 98-112 104
EDTA plasma (n=8) 97-112 104
Cell culture media (n=8) 86-96 91
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human ADH1 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 88-100 83-95 94-107
Average 95 90 100
1:4 Range 97-114 88-98 98-116
Average 104 93 106
1:8 Range 87-99 95-105 91-104
Average 92 100 98
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human ADH1. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ADH1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ADH1, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human ADH1. You can calculate the concentration of Human ADH1 in the samples by comparing the RLU value of the samples to the standard curve.
Human ADH1 (Alcohol Dehydrogenase 1) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定