Human ADIPOR2 (Adiponectin Receptor 2) CLIA Kit (E-CL-H0227)

Human ADIPOR2 (Adiponectin Receptor 2) CLIA Kit - 1
  • Human ADIPOR2 (Adiponectin Receptor 2) CLIA Kit - 1
  • Human ADIPOR2 (Adiponectin Receptor 2) CLIA Kit - 2
  • Human ADIPOR2 (Adiponectin Receptor 2) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 0.09 ng/mL
Detection Range 0.16-10 ng/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human ADIPOR2 in samples.No significant cross-reactivity or interference between Human ADIPOR2 and analogues was observed
Recovery 80%-120%
Sample Type Tissue homogenates, cell lysates and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
ng/mL OD1 OD2 Mean OD Corrected OD
10 33226.000 33340.000 33283.000 33249
5 14940.000 17664.000 16302.000 16268
2.5 7872.000 7728.000 7800.000 7766
1.25 3532.000 4138.000 3835.000 3801
0.63 1834.000 1732.000 1783.000 1749
0.31 925.000 815.000 870.000 836
0.16 360.000 366.000 363.000 329
0 33.000 35.000 34.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(ng/mL) 0.550 1.150 4.890 0.540 1.220 4.860
Standard deviation 0.040 0.100 0.520 0.050 0.100 0.400
CV(%) 7.270 8.700 10.630 9.260 8.200 8.230
Recovery
The recovery of Human ADIPOR2 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 95-111 101
EDTA plasma (n=8) 96-112 104
Cell culture media (n=8) 91-102 97
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human ADIPOR2 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 102-116 93-109 99-113
Average 108 101 105
1:4 Range 99-118 99-111 95-109
Average 107 104 101
1:8 Range 95-110 83-97 87-99
Average 101 90 94
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human ADIPOR2. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ADIPOR2 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ADIPOR2, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human ADIPOR2. You can calculate the concentration of Human ADIPOR2 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 79602
Uniport ID Q86V24
Research Area Cancer , Cardiovascular , Metabolism , Signal Transduction
Human ADIPOR2 (Adiponectin Receptor 2) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定