Human COL4α1 (Collagen Type Ⅳ Alpha 1) CLIA Kit (E-CL-H0559)

All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 37.5 pg/mL
Detection Range 62.5-4000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human COL4α1 in samples.No significant cross-reactivity or interference between Human COL4α1 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
4000 59803.000 60663.000 60233.000 60205
2000 27725.000 28611.000 28168.000 28140
1000 14812.000 12820.000 13816.000 13788
500 6290.000 7376.000 6833.000 6805
250 3408.000 3078.000 3243.000 3215
125 1641.000 1595.000 1618.000 1590
62.5 726.000 816.000 771.000 743
0 27.000 29.000 28.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human COL4α1 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human COL4α1 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 191.550 542.220 1620.450 199.400 585.880 1500.570
Standard deviation 23.540 42.560 130.770 20.580 47.690 137.900
CV(%) 12.290 7.850 8.070 10.320 8.140 9.190
Recovery
The recovery of Human COL4α1 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 83-99 90
EDTA plasma (n=8) 101-117 107
Cell culture media (n=8) 94-107 99
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human COL4α1 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 103-120 88-99 98-110
Average 109 94 103
1:4 Range 98-114 101-119 92-110
Average 107 109 100
1:8 Range 93-107 87-102 94-107
Average 100 93 100
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human COL4α1. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human COL4α1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human COL4α1, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human COL4α1. You can calculate the concentration of Human COL4α1 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 1282
Uniport ID P02462
Research Area Cancer , SignalTransduction , Stemcells
Human COL4α1 (Collagen Type Ⅳ Alpha 1) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}