Facebook

All categories

  • All categories
  • Flow Cytometry Antibodies
  • Immunoassays
  • Antibodies and Reagents
  • Cell Identification Kits
  • Cell Isolation Products
  • Cell Health and Metabolism Assay Kits
  • Proteins and Peptides
  • Cell Culture
Please enter the item number/product keyword!
Keyword cannot be empty !
INSERT SYMBOLS:
  • α
  • β
  • γ
  • δ
  • ε
  • ζ
  • η
  • θ
  • κ
  • μ
  • ω
  • σ
  • τ
  • λ
  • ⅩⅢ
  • ⅩⅢ
  • ⅩⅣ
  • ⅩⅤ
  • ⅩⅦ
  • ⅩⅧ
  • UP ↑

Human CTXI(Cross Linked C-telopeptide of Type I Collagen) CLIA Kit (E-CL-H0583)

Human CTXI(Cross Linked C-telopeptide of Type I Collagen) CLIA Kit  - 1
  • Human CTXI(Cross Linked C-telopeptide of Type I Collagen) CLIA Kit  - 1
  • Human CTXI(Cross Linked C-telopeptide of Type I Collagen) CLIA Kit  - 2
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 18.75 pg/mL
Detection Range 31.25-2000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human CTXI in samples.No significant cross-reactivity or interference between Human CTXI and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
2000 410321.000 408954.000 409637.000 408059
1000 353363.000 352403.000 352883.000 351304
500 281454.000 284347.000 282900.000 281322
250 237412.000 223073.000 230242.000 228664
125 148900.000 146578.000 147739.000 146160
62.5 79340.000 79603.000 79471.000 77893
31.25 34291.000 34199.000 34245.000 32666
0 1632.000 1525.000 1578.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 99.670 266.750 904.020 98.120 242.460 814.470
Standard deviation 5.300 11.840 40.860 5.230 12.750 27.610
CV(%) 5.320 4.440 4.520 5.330 5.260 3.390
Recovery
The recovery of Human CTXI was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 87-101 94
EDTA plasma (n=8) 85-100 92
Cell culture media (n=8) 85-98 92
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human CTXI and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 94-107 90-101 92-103
Average 101 96 98
1:4 Range 96-108 91-107 87-101
Average 103 98 94
1:8 Range 94-105 92-105 87-99
Average 99 97 94
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human CTXI. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CTXI and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CTXI, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human CTXI. You can calculate the concentration of Human CTXI in the samples by comparing the RLU value of the samples to the standard curve.
Research Area Metabolism , Cardiovascular , Cancer
Human CTXI(Cross Linked C-telopeptide of Type I Collagen) CLIA Kit  - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定