Human CXCR3 (Chemokine CXC Receptor 3) CLIA Kit (E-CL-H0592)

Human CXCR3 (Chemokine CXC Receptor 3) CLIA Kit - 1
  • Human CXCR3 (Chemokine CXC Receptor 3) CLIA Kit - 1
  • Human CXCR3 (Chemokine CXC Receptor 3) CLIA Kit - 2
  • Human CXCR3 (Chemokine CXC Receptor 3) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 18.75 pg/mL
Detection Range 31.25-2000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human CXCR3 in samples.No significant cross-reactivity or interference between Human CXCR3 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
2000 51390.000 62764.000 57077.000 57046
1000 22375.000 26517.000 24446.000 24415
500 11705.000 11545.000 11625.000 11594
250 4946.000 5674.000 5310.000 5279
125 2833.000 2809.000 2821.000 2790
62.5 1404.000 1334.000 1369.000 1338
31.25 673.000 701.000 687.000 656
0 30.000 32.000 31.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 110.690 194.550 842.020 110.240 180.000 856.080
Standard deviation 11.180 18.400 56.670 9.890 15.140 88.090
CV(%) 10.100 9.460 6.730 8.970 8.410 10.290
Recovery
The recovery of Human CXCR3 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 95-107 100
EDTA plasma (n=8) 86-99 93
Cell culture media (n=8) 100-114 106
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human CXCR3 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 93-108 96-113 86-99
Average 101 104 91
1:4 Range 102-115 93-107 101-115
Average 109 99 109
1:8 Range 92-108 95-109 96-113
Average 100 102 103
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human CXCR3. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CXCR3 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CXCR3, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human CXCR3. You can calculate the concentration of Human CXCR3 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 2833
Uniport ID P49682
Research Area Cancer , Cardiovascular , Immunology , Signal Transduction
Human CXCR3 (Chemokine CXC Receptor 3) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定